Evidence map›Paper›PMID 40242830›Full record

ArticleJournal of spine surgery (Hong Kong)2025

A new minimally invasive cervical pedicle screw (CPS) fixation system using intra-operative computed tomography-guided navigation.

Christian Blume, Tobias Philip Schmidt, Christian-Andreas Mueller, Alexander Romagna, Miguel Pishnamaz, Hans Clusmann, Ulf Bertram

Abstract read
In one paragraph

Article in Journal of spine surgery (Hong Kong), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. [Surgical management of spinal metastases].Orthopadie (Heidelberg, Germany) · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christian Blume *Department of Neurosurgery, RWTH Aachen University Hospital, Aachen, Germany.
Tobias Philip Schmidt *Department of Neurosurgery, RWTH Aachen University Hospital, Aachen, Germany.
Christian-Andreas MuellerDepartment of Neurosurgery, RWTH Aachen University Hospital, Aachen, Germany.
Alexander RomagnaDepartment of Neurosurgery, Muenchen Klinik Bogenhausen, Munich, Germany.
Miguel PishnamazDepartment of Orthopaedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Aachen, Germany.
Hans ClusmannDepartment of Neurosurgery, RWTH Aachen University Hospital, Aachen, Germany.
Ulf BertramDepartment of Neurosurgery, RWTH Aachen University Hospital, Aachen, Germany.ORCID https://orcid.org/0000-0002-5907-5213

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Since its introduction, placement of cervical pedicle screws (CPS) has been considered a procedure with a very high-risk profile. Minimally invasive CPS placement was not even considered at all. However, as surgical techniques and image guided intra-operative navigation have been refined over the last decade, navigated CPS placement has become a standard procedure in well-established spine centers. Currently, the first off-the-shelf percutaneous CPS placement platforms are becoming available. The aim of this study is to assess feasibility and accuracy of an minimally invasive surgery (MIS) CPS fixation system in a pilot series. Methods: Between January and July 2023, we treated a cohort of ten patients using a new cervical MIS platform. Forty pedicle screws were inserted percutaneously in the c-spine using intra-operative computed tomography (CT) guided navigation and retrospectively analysed for accuracy using a modified Gertzbein & Robbins (G&R) classification. Adverse events and other patient-related data were also documented. Results: Ninety percent of all screws were placed accurately (80% on perfect trajectory, 10% showed minor perforations). Another 10% (four screws) caused pedicle wall breaches between 2 and 4 mm, but were not revised, since misplacement was not associated with neurological deficit or inferior biomechanics. One patient experienced neurological deterioration, but not associated with screw misplacement. The transverse foramen was breached twice, however not endangering the vertebral arteries. Conclusions: In this pilot series MIS CPS placement yielded accurate placement rates comparable to open surgical approaches reported in the literature. Hence, MIS CPS placement appears to be a feasible and safe procedure in selected cases.

Indexed as

Cervical pedicle screws (CPS)computer-assisted surgery (CAS)instrumented fusionminimally invasive surgery (MIS)navigation

Identifiers

PMID40242830
PMCPMC11998035

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.