Evidence map›Paper›PMID 40241510›Full record

ArticleThe Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology2025

Normal Values in Esophageal High-Resolution Manometry Performed Using 36-Channel Water-Perfused Catheter or Solid-State Catheter.

Serhat Bor, Anahita Sadeghı, Sezgi Kıpcak, Ali Senkaya

Abstract read
In one paragraph

Article in The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Achalasia: Physician Practices and Knowledge in Türkiye.The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology · 2026
    Article
  2. Know Thy Kit-Why Catheter Design Matters!The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Serhat BorDivision of Gastroenterology, Ege University Medical School, İzmir, Türkiye.
Anahita SadeghıDigestive Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Sezgi KıpcakDivision of Gastroenterology, Ege University Medical School, İzmir, Türkiye.
Ali SenkayaDepartment of Gastroenterology, Ministry of Health İzmir City Hospital, İzmir, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/Aims: Manometric measurements are crucial for diagnosing esophageal motility disorders. High-resolution manometry (HRM) studies mainly use 2 catheter systems: solid state (SS) and water perfused (WP), each with distinct advantages. This study aimed to establish normal values for esophageal manometry using both 36-channel WP and SS catheters in healthy volunteers. Materials and Methods: This study, conducted between January 2017 and September 2018, included 44 healthy volunteers with no upper gastrointestinal symptoms or history of gastrointestinal surgery (except inguinal hernia repair or appendectomy). Participants gave written informed consent, abstained from medications and alcohol, and underwent normal endoscopy. They then had 2 consecutive esophageal manometry sessions, 1 day apart, using a 36-channel SS-HRM catheter and a 36-channel WP-HRM catheter. All tracings were analyzed using the Chicago classification version 3.0. Results: Four participants were excluded due to gastroesophageal reflux disease (GERD). Of the remaining 40 (age 37.4 ± 7.6, 62.5% male), all underwent WP-HRM, and 34 underwent SS-HRM. In SS-HRM, 74 of 386 swallows were <450 mm Hg·s·cm; in WP-HRM, 151 of 441 swallows were <<450 mm Hg·s·cm. Thus, 4 of 34 volunteers (11.8%) in SS-HRM and 12 of 40 (30%) in WP-HRM had ≥50% swallows with DCI <450 mm Hg·s·cm. Median IRP4 was 17 (7-27) mm Hg in SS-HRM vs. 6 (0-18) mm Hg in WP-HRM. The 5th-95th percentile DCI was 183-2962 mm Hg·s·cm in SS-HRM vs. 65.5-1711.5 mm Hg·s·cm in WP-HRM. Conclusion: This study compares normal values and differences in WP-HRM and SS-HRM among healthy Turkish volunteers, demonstrating differing diagnostic criteria and providing valuable reference data for future studies.

Indexed as

Esophageal motility disordersmanometrysolid-state high-resolution manometrywater-perfused high-resolution manometry

Identifiers

PMID40241510
PMCPMC12344881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.