Formal validation of a deep learning-based automated interpretation system for cardiac structure and function in adult echocardiography.

Guijuan Peng, Rongbo Ling, Xiaohua Liu, Qian Liu, Xiaofang Zhong, Yuanyuan Sheng, Yingqi Zheng, Shuyu Luo, Yumei Yang, Xiaoxuan Lin and 7 more

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Guijuan Peng *Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Rongbo Ling *The National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.
Xiaohua Liu *Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Qian LiuDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Xiaofang ZhongDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Yuanyuan ShengDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Yingqi ZhengDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Shuyu LuoDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Yumei YangDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Xiaoxuan LinDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Keming TangThe National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.
Jialan ZhengThe National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.
Lixin ChenDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Dong NiThe National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.
Jinfeng XuDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Yingying LiuDepartment of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.
Wufeng XueThe National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate measurement of cardiac structure and function is the basis of diagnosis of cardiac diseases, but it is time-consuming and empirically-dependent. This study attempted to propose a deep learning (DL) interpretation of cardiac structure and function. Methods: The training dataset consisted of 416 video loops and 892 Doppler images drawn from 141 patients undergoing clinical echocardiography from 2020 to 2021. Two experts labeled these images using the Pair platform. From this, DL algorithms including the Auto-Echo and Auto-Doppler were trained to measure echocardiographic parameters. Subsequently, eight sonographers with different years of echocardiographic experience labeled a validation dataset of 178 new video loops and 391 Doppler images obtained from 60 new patients. One highly trained expert annotated the external validation dataset of 90 two-dimensional (2D) videos and 120 Doppler images. The standard deviation ratio (SD ratio), Bland-Altman analysis, interclass correlation coefficient (ICC), mean absolute deviation (MAD), absolute relative deviation, and correlation analysis were employed to investigate the agreement between DL and human experts. Results: For the structure parameters' measurements including four-chamber dimensions, the SD ratios ranged from 0.70 to 1.02, and the ICCs showed that automated measurements were equivalent or superior to human expert measurements. The correlation coefficients were greater than 0.85 for 83.3% of the parameters, the MADs ranged from -1.5 to 1.9 mm, and the absolute relative deviations ranged from 2.5% to 9.7%. However, large absolute deviations were observed for parameters in RV-A4C view and RV, which was consistent with human readers. For Doppler parameters, including four transvalvular velocity measurements, the correlation coefficients ranged from 0.81 to 0.99, the absolute relative deviation of all pulse Doppler parameters was within 10%, and 100% (9/9) of tissue Doppler parameters were within 5%. However, the velocity-time integral (VTI) of transvalvular velocity showed large absolute relative deviations between the automated and manual measurements. Auto-Echo saved 95.4% and Auto-Doppler saved 82.5% analysis time upon human experts. In the external validation cohort, the mean absolute relative deviation for almost all structural parameters and Doppler parameters was within 10%. Conclusions: The measurements of our DL interpretation had high accuracy, increased efficiency of the examination, and were inter-changeable with human experts' assessment. It has shown human-like patterns of measurements, as the same trend of difference can be observed between DL and different experienced readers.

Indexed as

cardiac chamberDeep learning (DL)echocardiographypulsed-wave Dopplerquantification

Identifiers

PMID40235804
PMCPMC11994521

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.