Evidence map›Paper›PMID 40235759›Full record

ArticleQuantitative imaging in medicine and surgery2025

Retrospective study on preoperative hook wire localisation of pulmonary ground-glass nodules: risk factors for complications and preventive strategies.

Chuanxi Wang, Chang Chen, Gaohua Liu, Zhiquan Li, Delai Zheng, Xiaoliang Li

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Computed tomography-guided suture anchor localizer placement for multiple pulmonary nodule localization.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chuanxi WangDepartment of Cardiothoracic Surgery, The First People's Hospital of Neijiang, Neijiang, China.
Chang ChenDepartment of Pathology, West China Hospital of Sichuan University, Chengdu, China.
Gaohua LiuDepartment of Cardiothoracic Surgery, The First People's Hospital of Neijiang, Neijiang, China.
Zhiquan LiDepartment of Nuclear Medicine, The First People's Hospital of Neijiang, Neijiang, China.
Delai ZhengDepartment of Cardiothoracic Surgery, The First People's Hospital of Neijiang, Neijiang, China.
Xiaoliang LiDepartment of Cardiothoracic Surgery, The First People's Hospital of Neijiang, Neijiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Adjusting the angle of the trajectory needle may help reduce the occurrence of complications associated with preoperative hook and thread localisation. This study aims to examine the risk factors for complications associated with preoperative hook wire localisation of pulmonary ground-glass nodules (GGNs). Methods: In this single-centre retrospective study, an analysis was conducted on 230 preoperative hook wire implantations for 230 pulmonary GGNs. We assessed the angle of needle trajectory by analysing the computed tomography (CT) images at the point of needle insertion. We evaluated the main variables related to patient demographics, lesion size and location and preoperative conditions to determine the risk factors for complications. Univariate and multivariate logistic regression analyses were used to establish a predictive model to evaluate the incidence of hook wire localisation complications. Results: A total of 230 patients were included in the final analysis. Pneumothorax and intrapulmonary hemorrhage were the primary complications, occurring in 38.7% and 18.7% of cases, respectively. The results from the multivariate logistic regression analysis demonstrated a positive correlation between the needle insertion angle and the occurrence of pneumothorax [odds ratio (OR): 1.035, 95% confidence interval (CI): 1.008-1.063, P=0.011] as well as intrapulmonary hemorrhage (OR: 1.057, 95% CI: 1.020-1.095, P=0.002). Pneumothorax was associated with factors such as emphysema (OR: 12.286, 95% CI: 3.687-40.938, P<0.001), the nearest pleural distance (OR: 0.944, 95% CI: 0.907-0.983, P=0.005), and the number of punctures (OR: 3.443, 95% CI: 2.006-5.907, P<0.001). Similarly, pulmonary hemorrhage was correlated with variables such as the number of punctures (OR: 1.894, 95% CI: 1.080-3.322, P=0.026), chest wall access thickness (OR: 0.951, 95% CI: 0.915-0.988, P=0.010), and the length of intrapulmonary access (OR: 1.060, 95% CI: 1.016-1.106, P=0.007). Conclusions: In summary, reducing the needle trajectory angle can alleviate complications linked to preoperative hook wire localisation, and employing predictive models before puncture site selection, along with strategic needle insertion planning, can effectively minimise procedural risks.

Indexed as

angle of the needle trajectorycomplicationspredictive modelspreoperative localisationPulmonary ground-glass nodules (pulmonary GGNs)

Identifiers

PMID40235759
PMCPMC11994520

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.