Evidence map›Paper›PMID 40234559›Full record

ArticleScientific reports2025

Clinical evaluation of the installation conditions and accuracy of wearable neonatal jaundice meter.

Azusa Uozumi, Ibuki Ohara, Masaki Shimamura, Kazuhiro Iwama, Ayako Fukuyama, Haruko Horiguchi, Yutaka Isoda, Fumiya Kimura, Hiroki Ota, Shuichi Ito

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Azusa UozumiDepartment of Pediatrics, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa, 236-0004, Japan.
Ibuki OharaDepartment of Mechanical Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa, 240-8501, Japan.
Masaki ShimamuraDepartment of Mechanical Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa, 240-8501, Japan.
Kazuhiro IwamaDepartment of Pediatrics, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa, 236-0004, Japan.
Ayako FukuyamaDepartment of Pediatrics, National Hospital Organization Yokohama Medical Center, 3-60-2, Harajyuku, Totsuka-ku, Yokohama, Kanagawa, 245-8575, Japan.
Haruko HoriguchiDepartment of Pediatrics, Japan Organization of Occupational Health and Safety, Yokohama Rosai Hospital, 3211 Kozukue-cho, Kohoku-ku, Yokohama, Kanagawa, 222-0036, Japan.
Yutaka IsodaDepartment of Mechanical Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa, 240-8501, Japan.
Fumiya KimuraDepartment of Mechanical Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa, 240-8501, Japan.
Hiroki OtaDepartment of Mechanical Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa, 240-8501, Japan. ota-hiroki-xm@ynu.ac.jp.
Shuichi ItoDepartment of Pediatrics, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa, 236-0004, Japan. itoshu@yokohama-cu.ac.jp.

Funding

the Japan Agency for Medical Research and Development 21hm0102085h0002
6 · The paper itself

Abstract

Neonatal jaundice is a physiological phenomenon that occurs in newborns. However, because excess bilirubin can cause cytotoxicity, abnormal hyperbilirubinemia can lead to bilirubin encephalopathy. In the evaluation of neonatal jaundice, serum bilirubin concentrations are indirectly assessed via a transcutaneous bilirubinometer. However, commercially available transcutaneous bilirubinometers are expensive, especially in developing countries. Therefore, many newborns still suffer from bilirubin encephalopathy worldwide. We previously developed a prototype wearable jaundice meter. In this study, we aimed to investigate further improvements in this device and evaluate its measurement accuracy at different measurement sites and at different pressures. The bilirubin values of forty-eight newborns were measured at different sites (middle of the forehead and upper eyebrows) and with different pressures (1 and 2 newtons). The transcutaneous bilirubin values measured by the wearable bilirubin meter were strongly correlated with the transcutaneous bilirubin values measured by a commercially available bilirubin meter (r > 0.9) and the actual serum bilirubin values (> 0.84), even under different conditions. This wearable jaundice meter is much cheaper and smaller than commercially available jaundice meters and is a novel medical device that could be useful for evaluating neonatal jaundice.

Indexed as

BilirubinJaundice, NeonatalWearable Electronic DevicesFemaleHumansInfant, NewbornMaleNeonatal ScreeningBilirubinBilirubinJaundiceNeonatalNeonatal screeningWearable electronic devices

Identifiers

PMID40234559
PMCPMC12000441

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.