ArticleAnalytical chemistry2025
Centrifugal Microfluidic Lateral Flow Assay Enables High Sensitivity Interleukin-6 Detection and Ultrafast Readout of Elevated Analyte Levels.
Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The evolution of next-generation lateral flow assays for bacterial and fungal diagnostics.Mikrochimica acta · 2026Review
- Interplay of the Mass Transport and Reaction Kinetics for Lateral Flow Immunoassay Integrated on Lab-on-Disc.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Balancing sensitivity and time to result is always a challenging part of the development of analytical tools and is of particular importance in clinical and point-of-care diagnostics. In this study, a highly sensitive fluorescence interleukin-6 lateral flow assay (LFA) was developed using centrifugal microfluidics. The sample flow rate through the lateral flow membrane is determined by centrifugal force, which can be precisely controlled with a processing device. Using this precise flow control, an ultrafast early readout after 30 s with a sensitivity of 78.3 pg/mL and a quantitative measurement up to 2000 pg/mL was achieved. Afterward, the flow rate was reduced, and thus, the incubation time increased to achieve a maximum sensitivity of 1.2 pg/mL within 13 min of run time. This high-performance LFA is intended to help particularly vulnerable patient groups, such as pregnant women and neonates, where a rapid and highly sensitive diagnosis of inflammatory biomarkers can make a life-saving difference. In addition to medical applications, the presented system can also be used for the analysis of binding kinetics directly on the lateral flow strip. This enables the development of lateral flow assays with the highest possible sensitivity in the shortest time. Therefore, this advancement leads to a new era of point-of-care testing with future prospects for fully automated centrifugal cassettes with enhanced performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.