Evidence map›Paper›PMID 40229139›Full record

ArticleMedical physics2025

Automatic, machine-agnostic, convolution-based beam, and fluence modeling for Monte Carlo independent dose calculation.

Mingli Chen, Jingying Lin, Yang Park, Mu-Han Lin, Arnold Pompos, Andrew Godley, Weiguo Lu

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mingli ChenUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Jingying LinUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Yang ParkUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Mu-Han LinUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Arnold PomposUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Andrew GodleyUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.
Weiguo LuUniversity of Texas Southwestern Medical Center, Dallas, Texas, USA.

Funding

High-Precision Lung Radiotherapy by Intra-treatment Dynamic Cone-beam CT imaging and Dosimetry-guided Plan AdaptationR01EB034691 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI Weiguo Lu, You Zhang · 2024 to 2026
$1.5M
NIBIB NIH HHS R01 EB034691NIH HHS 1R01EB034691-01
6 · The paper itself

Abstract

backgroundMonte Carlo (MC)-based independent dose calculation is increasingly sought after for plan- and delivery-specific quality assurance (QA) in modern radiotherapy because of its high accuracy. It is particularly valuable for online adaptive radiotherapy, where measurement-based QA solutions are impractical. However, challenges related to beam modeling, commissioning, and plan/delivery-specific fluence calculation have hindered its widespread clinical adoption. PURPOSE: We propose a generic, automated, convolution-based beam and fluence modeling method for MC dose calculation, assuming zero or very limited knowledge of the linear accelerator (LINAC) head, with all necessary information derived from water phantom measurements. Instead of conventional particle transport through beam modulation devices (the phase space-based approach), we developed a direct convolution-based method to model the effects of beam modulation devices on output factors and fluence for downstream particle transport in the patient's body.

methodsThe measurement data necessary for the beam model include the percent depth dose (PDD) profile of a reference field (typically 10 × 10 cm

resultsCompared to reference beam data, our calculations achieved average gamma passing rates of over 97% using the 2%/2 mm criteria. Compared to a sample of 20 clinical plans calculated by the treatment planning systems (TPS) across different beam modalities and treatment machines, our calculated dose achieved gamma passing rates of over 97% using the 3%/2 mm criteria with an average calculation time of less than 1 min.

conclusionsThe proposed machine-agnostic, convolution-based beam, and fluence modeling approach enabled efficient automatic commissioning for a wide range of clinical external photon beam machines. The fluence map-based dose calculation approached sub-minute dose calculation efficiency for arbitrary treatment plans. The proposed method has the potential to accelerate the adoption of MC calculation-based QA for online adaptive radiotherapy.

Indexed as

Monte Carlo MethodRadiation DosageRadiotherapy Planning, Computer-AssistedAutomationHumansParticle AcceleratorsPhantoms, ImagingRadiotherapy Dosagebeam modelingindependent dosemonte carlo dose

Identifiers

PMID40229139
PMCPMC12257457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked