Evidence map›Paper›PMID 40228547›Full record

ArticleJornal de pediatria

Comparison of electrical bioimpedance in newborns with electrodes positioned on the right and left sides of the body.

Thatyana Ribeiro Medeiros, Camila Barros Melgaço da Silva, Flávia Nunes Benicio de Souza, Hannah Schmidel Kautsky, Luana Martins de Oliveira, Luana Martins de Toledo, Alan Araújo Vieira

Abstract readComparative Study
In one paragraph

Article in Jornal de pediatria. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Thatyana Ribeiro MedeirosUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil. Electronic address: thatyanam@id.uff.br.
Camila Barros Melgaço da SilvaUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.
Flávia Nunes Benicio de SouzaUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.
Hannah Schmidel KautskyUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.
Luana Martins de OliveiraUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.
Luana Martins de ToledoUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.
Alan Araújo VieiraUniversidade Federal Fluminense, Faculdade de Medicina, Departamento Materno Infantil, Niterói, RJ, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveBioelectrical impedance analysis is a method used to assess body composition; a noninvasive test performed using an easy-to-handle portable device used in clinical practice. However, nonstandard methods in neonates hinder external validation and reliability. Currently, bioimpedance analysis is performed in newborns with electrodes positioned on the right side of the body; however, the use of medical devices, including vascular access, can prevent its use.

methodsAn uncontrolled before-after clinical trial comparing resistance and reactance measurements by bioelectrical impedance analysis on both sides was conducted. Measurements were performed immediately after the randomization of the initial measurement side. The sample size was calculated by considering a 10% deviation from the mean resistance and reactance values of previous studies with alpha and beta errors of 10% and 20%, respectively. Binary linear regression was used to quantify the correlation.

resultsA significant difference was observed between resistance (672.88 ± 136.30 vs. 649.22 ± 119.59) and reactance (46.34 ± 17.99 vs. 44.439 ± 19.42) values measured on the right and left sides, respectively. However, when measured on both sides of the body, resistance and reactance values showed a good correlation (0.98 for both models, p < 0.001). Positioning the electrodes on the left side significantly affected the resistance and reactance values measured by bioelectrical impedance analysis compared with those on the right side.

conclusionElectrodes positioned on opposite sides of the body generated different resistance and reactance values, implying the need to use the right side exclusively for standard positioning. This restriction can create difficulties for the routine use of this technique in newborns.

Indexed as

Body CompositionElectric ImpedanceElectrodesFemaleHumansInfant, NewbornMaleReproducibility of ResultsBody compositionElectrical impedanceNewborn