Evidence map›Paper›PMID 40228178›Full record

ArticlePloS one2025

A data-driven approach for real-time soft tissue deformation prediction using nonlinear presurgical simulations.

Haolin Liu, Ye Han, Daniel Emerson, Yoed Rabin, Levent Burak Kara

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Haolin LiuDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America.ORCID 0000-0002-9237-5613
Ye HanDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America.
Daniel EmersonDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America.ORCID 0009-0000-2149-0553
Yoed RabinDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America.
Levent Burak KaraDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America.ORCID 0000-0002-2203-4020

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A method that allows a fast and accurate registration of digital tissue models obtained during preoperative, diagnostic imaging with those captured intraoperatively using lower-fidelity ultrasound imaging techniques is presented. Minimally invasive surgeries are often planned using preoperative, high-fidelity medical imaging techniques such as MRI and CT imaging. While these techniques allow clinicians to obtain detailed 3D models of the surgical region of interest (ROI), various factors such as physical changes to the tissue, changes in the body's configuration, or apparatus used during the surgery may cause large, non-linear deformations of the ROI. Such deformations of the tissue can result in a severe mismatch between the preoperatively obtained 3D model and the real-time image data acquired during surgery, potentially compromising surgical success. To overcome this challenge, this work presents a new approach for predicting intraoperative soft tissue deformations. The approach works by simply tracking the displacements of a handful of fiducial markers or analogous biological features embedded in the tissue, and produces a 3D deformed version of the high-fidelity ROI model that registers accurately with the intraoperative data. In an offline setting, we use the finite element method to generate deformation fields given various boundary conditions that mimic the realistic environment of soft tissues during a surgery. To reduce the dimensionality of the 3D deformation field involving thousands of degrees of freedom, we use an autoencoder neural network to encode each computed deformation field into a short latent space representation, such that a neural network can accurately map the fiducial marker displacements to the latent space. Our computational tests on a head and neck tumor, a kidney, and an aorta model show prediction errors as small as 0.5 mm. Considering that the typical resolution of interventional ultrasound is around 1 mm and each prediction takes less than 0.5 s, the proposed approach has the potential to be clinically relevant for an accurate tracking of soft tissue deformations during image-guided surgeries.

Indexed as

Computer SimulationImaging, Three-DimensionalModels, AnatomicHumansMagnetic Resonance ImagingMinimally Invasive Surgical ProceduresTomography, X-Ray ComputedUltrasonography

Identifiers

PMID40228178
PMCPMC11996222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.