SynthesisFrontiers in surgery2025
A systematic review of implant materials for facial reconstructive and aesthetic surgery.
Synthesis in Frontiers in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Integrated Perioperative Infection Management Measures (PSMS-11) for ePTFE Rhinoplasty in East Asian Patients: A Large-Sample, Long-Term Retrospective Study.Aesthetic plastic surgery · 2026Article
- Risk Factors and Complication Rates of Inpatient Genioplasty Procedures in the U.S. Healthcare System: A 22-Year Retrospective Multi-center Analysis.Aesthetic plastic surgery · 2026Article
- Strategies for Malar Implant Placement: A Review of Access, Planning, and Outcomes.Plastic and reconstructive surgery. Global open · 2026Article
- Facial Contouring in Orthognathic Surgery: The Role of Facial Implants.Craniomaxillofacial trauma & reconstruction · 2026Review
- Bimaxillary orthognathic surgery with mentoplasty and the use of porous polyethylene.Brazilian dental journal · 2026Article
- From Autologous Bone Tissue to Bioengineered Material Solutions in Post-Traumatic Orbital Wall Reconstruction: An Overview.Journal of functional biomaterials · 2025Review
- Overcoming the Limitations of Conventional Orthognathic Surgery: A Novel Approach Using Implate.Journal of clinical medicine · 2025Article
- Clinical and microscopic evidence of biofilm formation on titanium miniplates applied in maxillofacial surgery: a case series analysis.Case reports in plastic surgery & hand surgery · 2025Article
- Implant-Based Chin Augmentation Vs Osseous Genioplasty: A Systematic Review of Indications and Outcomes.Aesthetic surgery journal. Open forum · 2025Review
- Osseous Genioplasty and Its Impact on Airway Volume-What is the Evidence?Aesthetic surgery journal. Open forum · 2025Review
- Mandibular reconstruction with anterolateral thigh free flap and bridging plate: a retrospective study of 34 oncological cases.Frontiers in surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Assessing facial plastic surgery techniques is essential for improving patient safety and outcomes through evidence-based practices. Despite the extensive use of facial implants, there is a scarcity of thorough research on their long-term effects and safety profiles. Methods: A systematic review was conducted following PRISMA guidelines, analyzing studies from 1970 to 2024 on various implant materials for facial reconstruction and augmentation. The databases searched for this review included PubMed, Web of Science, Google Scholar, and EMBASE. Inclusion criteria were full-text articles in English, focusing on alloplastic materials for craniofacial skeleton replacement or augmentation. Results: We included 117 studies with 4,273 patients and a mean follow-up of 34 months (range: 15 days to 25 years). Of these, 56% focused on reconstruction, 33% on aesthetics, and 10% on both. Patient ages ranged from 6 months to 85 years, with most studies addressing the orbital (29%), chin (22%), and malar (19%) regions. 67% of studies evaluated potential complications and found an overall rate of 4.4%. Nerve injuries (2.1%) and infections (1.0%) were the most frequent issues, with hematoma, implant displacement, and bone resorption rates at 1.4%, 0.59%, and 0.68%, respectively. Patient-specific implants (PSIs) showed promise in reducing complications such as infections, suggesting that customization to patient anatomy may provide benefits. The highest rate of complication-free postoperative recovery was observed with polyethylene facial implants. Conclusion: This review highlights variability in implant performance. The increased use of PSI suggests improved outcomes, warranting further investigation. Standardized outcome reporting and further research are needed to enhance comparability and guide clinical practice. Systematic Review Registration: PROSPERO, identifier (CRD42024501754).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials