Evidence map›Paper›PMID 40224549›Full record

ArticleBrain circulation

Evaluation of an endovascular aneurysm model in pigs for chronic experiments.

Lara Bender, Thorsten Sichtermann, Jan Minkenberg, Christoph Dorn, Rebecca May, Charlotte S Weyland, Dimah Hasan, Andrea Stockero, Hani Ridwan, Martin Wiesmann and 2 more

Abstract read
In one paragraph

Article in Brain circulation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Lara BenderDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Thorsten SichtermannDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Jan MinkenbergDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Christoph DornDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Rebecca MayDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Charlotte S WeylandDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Dimah HasanDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Andrea StockeroDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Hani RidwanDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Martin WiesmannDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Omid NikoubashmanDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Christiane FranzDepartment of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsCerebral aneurysms are a potentially life-threatening condition for humans. Due to the anatomical variability of different aneurysm types in human patients, animal models are indispensable for endovascular research. The aim of our study was to evaluate an endovascular aneurysm model in chronical experiments using 12 female Aachen minipigs. MATERIALS AND

methodsFor aneurysm creation in external carotid and subclavian arteries, Amplatzer vascular plugs were used as occlusion devices, leaving simple stumps that serve as surrogate aneurysms. If necessary and anatomically possible, additional embolic materials, such as coils and liquid embolic agents were used.

resultsWe created 42 aneurysms. Aneurysm creation was possible without complications in all cases. There was no spontaneous thrombosis of fabricated aneurysms. Complete perfusion arrest behind the fabricated aneurysm was challenging but achieved in 45% of cases. We were not able to identify significant factors that have an impact on the persisting perfusion of fabricated aneurysms on final imaging, particularly not the presence of side branches in the aneurysm lumen (

conclusionDespite its limitations, including persistent perfusion and impaired predictability for long-term experiments, the endovascular aneurysm model shows potential to replace certain surgical models and offers broad applications in biomedical research and aneurysm therapy.

Indexed as

Aachen minipigendovascular animal modelexternal carotic arteryintracranial in vivo modelneuroradiologysubclavian artery

Identifiers

PMID40224549
PMCPMC11984821

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.