Evidence map›Paper›PMID 40221451›Full record

ArticleScientific reports2025

Automatic measurement of proximal femoral morphological parameters using point cloud semantic segmentation technology.

Yagang Wang, Qiulong Yang, Jiantao Li, Kaixuan Wang, Miaotian Tang

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yagang Wang *School of Computer, Xi'an University of Posts and Telecommunications, Xi'an, 710121, Shaanxi, People's Republic of China.
Qiulong YangSchool of Computer, Xi'an University of Posts and Telecommunications, Xi'an, 710121, Shaanxi, People's Republic of China. yangqiulong1998@163.com.
Jiantao LiDepartment of Orthopedics, The National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100853, People's Republic of China. lijiantao618@163.com.
Kaixuan Wang *Department of Orthopedics, The National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100853, People's Republic of China.
Miaotian TangDepartment of Trauma and Orthopedics, Peking University People's Hospital, Beijing, 100032, People's Republic of China. xiao1023@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper proposes a method for the automatic measurement of proximal femoral morphological parameters based on CT images. First, construct a statistical model of the femur with generalization properties and perform Mask labeling. Second, automatically segment the femur model from CT images to obtain the femur sample to be tested. Then, use the GBCPD point cloud registration algorithm to complete a fast hierarchical registration between the two models, establishing point-to-point correspondences. Based on these correspondences and femoral morphological features, automatically segment the test femur sample into the shaft, neck, and head. Numerical methods are used to determine the femoral shaft axis (using PCA combined with least-squares cylinder fitting), the femoral head center and radius (least-squares sphere fitting), as well as the eccentricity and femur length. We conducted reproducibility tests of this method on 213 femurs and compared the results between automatic segmentation/measurement and manual segmentation/measurement. The Dice similarity coefficients for the femoral head, neck, and shaft reached 0.98, 0.95, and 0.99, respectively. The reproducibility errors of the anatomical standards (angles, dimensions) for automatic measurement were all lower than the errors between manual measurements, indicating that the parameter values obtained by this method exhibit good consistency with the corresponding parameter values manually identified by medical experts in the original CT images. This effectively minimizes subjective influences and can assist orthopedic surgeons in large-scale measurement analysis.

Indexed as

FemurImage Processing, Computer-AssistedAlgorithmsFemaleFemur HeadHumansMaleReproducibility of ResultsTomography, X-Ray ComputedAutomatic measurementCT bone imageFemur morphometric parametersPoint cloud semantic segmentation

Identifiers

PMID40221451
PMCPMC11993577

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.