Evaluation of the two-voltage method for parallel-plate ionization chambers irradiated with pulsed beams.

José Paz-Martín, Andreas Schüller, Alexandra Bourgouin, Araceli Gago-Arias, Diego M González-Castaño, Nicolás Gómez-Fernández, Juan Pardo-Montero, Faustino Gómez

Abstract readEvaluation Study
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

José Paz-MartínDepartamento de Física de Partículas, Universidade de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain.
Andreas SchüllerDosimetry for Radiotherapy, Physikalisch-Technische Bundesanstalt, Braunschweig, Germany.
Alexandra BourgouinNational Research Council of Canada, Metrology Research Center, Ottawa, ON, Canada.
Araceli Gago-AriasDepartamento de Física de Partículas, Universidade de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain.
Diego M González-CastañoLaboratorio de Radiofísica, Universidade de Santiago, Santiago de Compostela, A Coruña, Spain.
Nicolás Gómez-FernándezLaboratorio de Radiofísica, Universidade de Santiago, Santiago de Compostela, A Coruña, Spain.
Juan Pardo-MonteroGroup of Medical Physics and Biomathematics, Instituto de Investigacion Sanitaria de Santiago (IDIS), Santiago de Compostela, A Coruña, Spain.
Faustino GómezDepartamento de Física de Partículas, Universidade de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain.

Funding

Agencia Estatal de Investigación PLEC2022-009476European Metrology Programme for Innovation and Research 18HLT04 UHDpulse'la Caixa' Foundation HR23-00718NextGenerationEU PLEC2022-009476Xunta de Galicia IN607D2022
6 · The paper itself

Abstract

backgroundAir-vented ionization chambers exposed to clinical radiation beams may suffer from recombination during the drift of the charge carriers towards the electrodes. Thus, dosimetry protocols recommend the use of a correction factor, usually denominated saturation factor ( PURPOSE: To evaluate the impact of a more realistic approach to the saturation problem that accounts for the free electron fraction.

methodsThe saturation factor of four ionization chambers (two Advanced Markus and two PPC05) was experimentally determined in the ultra-high dose per pulse reference beam of the German National Metrology Institute (Physikalisch-Technische Bundesanstalt [PTB]) for voltages ranging from 50 to 400 V and pulse durations between 0.5 and 2.9

resultsThe saturation factors calculated using the different Boag analytical models do not agree neither with each other nor with the numerical simulation even at the lowest dose per pulse of the investigated range (

conclusionsThe numerical simulation shows a better agreement with the experimental data than the current analytical theories in terms of CCE. The classical TVM, systematically overestimates the saturation factor, with differences increasing with dose per pulse but also present at low dose per pulse. These results may have implications for the dosimetry with ionization chambers in therapy modalities that use a dose per pulse higher than conventional radiotherapy such as intraoperative radiotherapy but also in conventional dose per pulse for ionization chambers that suffer from significant charge recombination.

Indexed as

ElectricityRadiometryrecombinationsaturation factortwo‐voltage method

Identifiers

PMID40219618
PMCPMC12149696

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.