ArticleMedical physics2025
Interplay-robust optimization for treating irregularly breathing lung patients with pencil beam scanning.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Interplay effect evaluation on lung and esophageal cancer patients treated with compact proton system in free breathing.Physics and imaging in radiation oncology · 2026Article
- Interplay-robust optimization for treating irregularly breathing lung patients with pencil beam scanning.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe steep dose gradients obtained with pencil beam scanning allow for precise targeting of the tumor but come at the cost of high sensitivity to uncertainties. Robust optimization is commonly applied to mitigate uncertainties in density and patient setup, while its application to motion management, called 4D-robust optimization (4DRO), is typically accompanied by other techniques, including gating, breath-hold, and re-scanning. In particular, current commercial implementations of 4DRO do not model the interplay effect between the delivery time structure and the patient's motion. PURPOSE: Interplay-robust optimization (IPRO) has previously been proposed to explicitly model the interplay-affected dose during treatment planning. It has been demonstrated that IPRO can mitigate the interplay effect given the uncertainty in the patient's breathing frequency. In this study, we investigate and evaluate IPRO in the context where the motion uncertainty is extended to also include variations in breathing amplitude.
methodsThe compared optimization methods are applied and evaluated on a set of lung patients. We model the patients' motion using synthetic 4D computed tomography (s4DCT), each created by deforming a reference CT based on a motion pattern obtained with 4D magnetic resonance imaging. Each (s4DCT) contains multiple breathing cycles, partitioned into two sets for scenario generation: one for optimization and one for evaluation. Distinct patient motion scenarios are then created by randomly concatenating breathing cycles varying in period and amplitude. In addition, a method considering a single breathing cycle for generating optimization scenarios (IPRO-1C) is developed to investigate to which extent robustness can be achieved with limited information. Both IPRO and IPRO-1C were investigated with 9, 25, and 49 scenarios.
resultsFor all patient cases, IPRO and IPRO-1C increased the target coverage in terms of the near-worst-case (5th percentile) CTV D98, compared to 4DRO. After normalization of plan doses to equal target coverage, IPRO with 49 scenarios resulted in the greatest decreases in OAR dose, with near-worst-case (95th percentile) improvements averaging 4.2 %. IPRO-1C with 9 scenarios, with comparable computational demands as 4DRO, decreased OAR dose by 1.7 %.
conclusionsThe use of IPRO could lead to more efficient mitigation of the interplay effect, even when based on the information from a single breathing cycle. This can potentially decrease the need for real-time motion management techniques that prolong treatment times and decrease patient comfort.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.