Evidence map›Paper›PMID 40218832›Full record

ArticleSensors (Basel, Switzerland)2025

ECG Sensor Design Assessment with Variational Autoencoder-Based Digital Watermarking.

Chih-Yu Hsu, Chih-Yin Chang, Yin-Chi Chen, Jasper Wu, Shuo-Tsung Chen

Abstract readEvaluation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chih-Yu HsuSchool of Transportation, Fujian University of Technology, Fuzhou 350118, China.ORCID 0000-0003-1074-8170
Chih-Yin ChangDepartment of Medical Informatics, Chung Shan Medical University, Taichung 40201, Taiwan.
Yin-Chi ChenDepartment of Medical Informatics, Chung Shan Medical University, Taichung 40201, Taiwan.
Jasper WuKang Chiao International School, Linkou Campus, New Taipei City 244, Taiwan.
Shuo-Tsung ChenDepartment of Electronic Engineering, National Kaohsiung University of Science and Technology, Kaohsiung City 807618, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Designing an ECG sensor circuit requires a comprehensive approach to detect, amplify, filter, and condition the weak electrical signals produced by the heart. To evaluate sensor performance under realistic conditions, diverse ECG signals with embedded watermarks are generated, enabling an assessment of how effectively the sensor and its signal-conditioning circuitry handle these modified signals. A Variational Autoencoder (VAE) framework is employed to generate the watermarked ECG signals, addressing critical concerns in the digital era, such as data security, authenticity, and copyright protection. Three watermarking strategies are examined in this study: embedding watermarks in the mean (μ) of the VAE's latent space, embedding them through the latent variable (z), and using post-reconstruction watermarking in the frequency domain. Experimental results demonstrate that watermarking applied through the mean (μ) and in the frequency domain achieves a low Mean Squared Error (MSE) while maintaining stable signal fidelity across varying watermark strengths (α), latent space dimensions, and noise levels. These findings indicate that the mean (μ) and frequency domain methods offer robust performance and are minimally affected by changes in these parameters, making them particularly suitable for preserving ECG signal quality. By contrasting these methods, this study provides insights into selecting the most appropriate watermarking technique for ECG sensor applications. Incorporating watermarking into sensor design not only strengthens data security and authenticity but also supports reliable signal acquisition in modern healthcare environments. Overall, the results underscore the effectiveness of combining VAEs with watermarking strategies to produce high-fidelity, resilient ECG signals for both sensor performance evaluation and the protection of digital content.

Indexed as

AutoencoderElectrocardiographySignal Processing, Computer-AssistedComputer SecurityHumansFourier-simulated ECG datasetlatent variable spacevariational AutoEncoderwatermarking technology

Identifiers

PMID40218832
PMCPMC11991367

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.