Evidence map›Paper›PMID 40216903›Full record

ArticleScientific reports2025

Reducing power ripple for multi-rotor wind energy systems using FOPDPI controllers.

Habib Benbouhenni, Ilhami Colak, Z M S Elbarbary, Shaik Mohammad Irshad

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Habib BenbouhenniDepartment of Electrical Engineering, LAAS laboratory, National Polytechnic School of Oran-Maurice Audin, BP 1523, Oran El M'naouer, Algeria. habib.benbouhenni@enp-oran.dz.
Ilhami ColakDepartment of Electrical and Electronics Engineering, Faculty of Engineering and Natural Science, Istinye University, Istanbul, Turkey.
Z M S ElbarbaryDepartment of Electrical Engineering, College of Engineering, King Khalid University, KSA, P.O. Box 394, Abha, 61421, Saudi Arabia.
Shaik Mohammad IrshadDepartment of Electrical Engineering, College of Engineering, King Khalid University, KSA, P.O. Box 394, Abha, 61421, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Energy systems based on wind energy have now become a necessity due to their many advantages. However, using traditional turbines has several disadvantages, the most notable of which is the low performance and quality of the resulting energy. This work proposes an energy system based on the use of a multi-rotor wind turbine (MRWT) with a double-fed induction generator. In addition, to obtain high-quality power, a new control is used based on the development and modification of direct power control (DPC) based on proportional-integral (PI) controllers. This designed approach has many advantages, such as fast dynamic response, easy adjustment, high robustness, and ease of implementation. In this designed technique, the PI controller is dispensed with, and they are replaced by the designed fractional-order proportional-integral proportional derivative controller. This designed technique is based on power estimation, where the same estimation equations used in the DPC-PI technique are used. Robustness, high competence, and effectiveness in improving power quality are among the most prominent features of the designed technique compared to the DPC-PI approach and some research works. The designed technique was verified using MATLAB, comparing the results obtained in the case of different wind speed profiles with those using the DPC-PI approach. Numerical results demonstrated the efficacy of the designed technique over the DPC-PI approach, as the steady-state error and active power ripples were minimized in the first test by rates estimated at 44.72% and 46.67%, respectively. Also, the reactive power overshoot and ripples were reduced in the fifth test by rates calculated at 81.40% and 42.18%, respectively. On the other hand, the total harmonic distortion of the current was minimized by rates estimated in the five suggested tests at 33.80%, 34.88%, 11.52%, 37.58%, and 33.33%. These percentages show the strength of the performance and effectiveness of the designed technique in enhancing the robustness and efficiency of the MRWT system, making it a promising solution.

Indexed as

Direct power controlFractional-order proportional derivative proportional-integral controllerMulti-rotor wind energy systemPulse width modulation

Identifiers

PMID40216903
PMCPMC11992050

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.