Evidence map›Paper›PMID 40214541›Full record

ArticleNanomaterials (Basel, Switzerland)2025

Enhanced Imaging in Scanning Transmission X-Ray Microscopy Assisted by Ptychography.

Shuhan Wu, Zijian Xu, Ruoru Li, Sheng Chen, Yingling Zhang, Xiangzhi Zhang, Zhenhua Chen, Renzhong Tai

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shuhan WuShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.ORCID 0009-0004-8726-9586
Zijian XuShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.ORCID 0000-0002-0006-5301
Ruoru LiShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.ORCID 0009-0001-8205-4998
Sheng ChenShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.ORCID 0009-0005-0469-5406
Yingling ZhangShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.
Xiangzhi ZhangShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.ORCID 0009-0006-5935-8383
Zhenhua ChenShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.
Renzhong TaiShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.

Funding

Ministry of Science and Technology of the People's Republic of China 2022YFA1603702, 2021YFA1601001National Natural Science Foundation of China 12335019, 11875316
6 · The paper itself

Abstract

Scanning transmission X-ray microscopy (STXM) is a direct imaging technique with nanoscale resolution. But its resolution is limited by the spot size on the sample, i.e., by the manufacturing technique of the focusing element. As an emerging high-resolution X-ray imaging technique, ptychography utilizes highly redundant data from overlapping scans as well as phase retrieval algorithms to simultaneously reconstruct a high-resolution sample image and a probe function. In this study, we designed an accurate reconstruction strategy to obtain the probe spot with the vibration effects being eliminated, and developed an image enhancement technique for STXM by combining the reconstructed probe with the deconvolution algorithm. This approach significantly improves the resolution of STXM imaging and can break the limitation of the focal spot on STXM resolution when the scanning step size is near or below the spot size, while the data processing time is much shorter than that of ptychography. Both simulations and experiments show that this approach can be applied to STXM data at different energies and different scan steps using the same focal spot retrieved via ptychography.

Indexed as

accurate probe reconstructiondeconvolutionimage enhancementptychographySTXM

Identifiers

PMID40214541
PMCPMC11990249

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.