Evidence map›Paper›PMID 40214538›Full record

ArticleNanomaterials (Basel, Switzerland)2025

Towards MRI Study of Biointegration of Carbon-Carbon Composites with Ca-P Coatings.

Victoria V Zherdeva, Petr E Zaitsev, Andrei S Skriabin, Alexey V Shakurov, Vladimir R Vesnin, Elizaveta S Skriabina, Petr A Tsygankov, Irina K Sviridova, Natalia S Sergeeva, Valentina A Kirsanova and 2 more

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Victoria V ZherdevaBach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow 119071, Russia.
Petr E ZaitsevBach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow 119071, Russia.
Andrei S SkriabinDepartment of Power Engineering, Bauman Moscow State Technical University, Moscow 105005, Russia.ORCID 0000-0002-8578-2632
Alexey V ShakurovDepartment of Power Engineering, Bauman Moscow State Technical University, Moscow 105005, Russia.
Vladimir R VesninDepartment of Power Engineering, Bauman Moscow State Technical University, Moscow 105005, Russia.
Elizaveta S SkriabinaDepartment of Power Engineering, Bauman Moscow State Technical University, Moscow 105005, Russia.ORCID 0009-0000-1881-2822
Petr A TsygankovSchool of Physics, Industrial University of Santander, Bucaramanga 680002, Colombia.ORCID 0000-0002-1221-9988
Irina K SviridovaP.A. Herzen Moscow Research Oncology Institute, Branch of FSBI "National Medical Research Radiological Centre", Ministry of Health of the Russian Federation, Moscow 125284, Russia.ORCID 0000-0003-0848-1542
Natalia S SergeevaP.A. Herzen Moscow Research Oncology Institute, Branch of FSBI "National Medical Research Radiological Centre", Ministry of Health of the Russian Federation, Moscow 125284, Russia.ORCID 0000-0001-7406-9973
Valentina A KirsanovaP.A. Herzen Moscow Research Oncology Institute, Branch of FSBI "National Medical Research Radiological Centre", Ministry of Health of the Russian Federation, Moscow 125284, Russia.ORCID 0000-0002-8806-9234
Suraya A AkhmedovaP.A. Herzen Moscow Research Oncology Institute, Branch of FSBI "National Medical Research Radiological Centre", Ministry of Health of the Russian Federation, Moscow 125284, Russia.ORCID 0000-0003-1861-6404
Natalya B SerejnikovaInstitute of Regenerative Medicine, I.M. Sechenov First Moscow State Medical University, Moscow 119991, Russia.ORCID 0000-0002-4097-1552

Funding

Russian Science Foundation 20-79-10190
6 · The paper itself

Abstract

The development of specific MRI criteria to monitor the implantation process may provide valuable information of individual tissue response. Using MRI and histological methods, the biointegration of carbon-carbon (C-C) composites into the subcutaneous tissues of BDF1 mice and their biocompatibility were investigated. The study focused on autopsy specimens containing C-C composite implants, both uncoated and coated with synthetic hydroxyapatite (Ca-P) via electrodeposition or detonation techniques, assessed at 6 and 12 weeks post-implantation. The results revealed that the radiological characteristics of the connective tissue capsule surrounding the implants allowed for the differentiation between loose and dense connective tissues. Fat-suppressed T1-weighted MRI scans showed that the volume of both loose and dense connective tissue in the capsule increased proportionally at 6 and 12 weeks, with distinct ratios observed between the coated and uncoated specimens. The proposed MRI criteria provided a strategy for evaluating the density and homogeneity of the connective tissue capsule. This approach could be valuable for further non-invasive in vivo studies on implant biointegration.

Indexed as

carbon-carbon medical compositesdetonation sprayingelectrophoretic depositionfibrous capsulehydroxyapatite coatingsMRIradiology studiestissue response

Identifiers

PMID40214538
PMCPMC11990118

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.