Evidence map›Paper›PMID 40211587›Full record

ArticleCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2025

Real Time Hemodynamic Monitoring During M-TEER Using Electrical Cardiometry.

Andreas Goldschmied, Manuel Sigle, Ioannis Toskas, Monika Zdanyte, Mareike Bladt, Meinrad Gawaz, Tobias Geisler

Abstract read
In one paragraph

Article in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andreas GoldschmiedDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.ORCID 0000-0002-0168-1755
Manuel SigleDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.
Ioannis ToskasDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.
Monika ZdanyteDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.
Mareike BladtDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.
Meinrad GawazDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.
Tobias GeislerDepartment of Cardiology, University Hospital Tübingen, Tübingen, Germany.

Funding

The ICON® electrical cardiometry system was provided by OSYPKA MEDICAL.
6 · The paper itself

Abstract

backgroundMitral regurgitation is a common valvular dysfunction causing patient morbidity and mortality. Mitral transcatheter edge-to-edge repair (M-TEER) allows grasping of valvular leaflets and approximation via a small implant, thus reducing mitral regurgitation (MR). The implant allows staged leaflet capture and leaflet optimization before it is finally released. Real time hemodynamic monitoring could facilitate procedural success and improve patient outcomes.

methodsFourteen patients scheduled for elective M-TEER were included in this study. Right heart catheterization (RHC) and determination of cardiac stroke volume (SV) using the established Fick method, pulmonary capillary wedge pressure (PCWP), PCWP v-wave, left atrial (LA) pressure and LA v-wave were carried out pre and postprocedurally. Concomitantly, real time SV was measured via electrical cardiometry and acquired data were compared.

resultsA significant increase in cardiac stroke volume measured via RHC was observed after successful M-TEER. Even though pre- and postprocedural RHC and electrical cardiometry measurements correlated significantly, electrical cardiometry was not able to reproduce the absolute increase in SV seen on RHC measurements. Furthermore, a decrease in PCWP mean pressure, PCWP v-wave, LA mean pressure and LA v-wave, were observed.

conclusionCardiac SV increases after successful M-TEER as measured via RHC but electrical cardiometry was not able to reproduce these changes in a real time, beat-to-beat measurement.

Indexed as

Cardiac CatheterizationEchocardiography, TransesophagealHeart Valve Prosthesis ImplantationHemodynamic MonitoringHemodynamicsMitral ValveMitral Valve InsufficiencyAgedAged, 80 and overFemaleHeart Valve ProsthesisHumansMaleMiddle AgedPredictive Value of TestsStroke Volumeelectrical cardiometryhemodynamicsmitral regurgitationM‐TEERright heart catheter

Identifiers

PMID40211587
PMCPMC12231150

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.