Evidence map›Paper›PMID 40211008›Full record

ArticleScientific reports2025

Image quality evaluation of imaging skins, a novel stretchable X-ray detector for intraoperative tumour imaging.

Solène Dietsch, Harry Allan, Lukas Lindenroth, Robert Moss, Agostino Stilli, Danail Stoyanov

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Imaging skins: stretchable Gd2O2S:Tb X-ray detectors for image-guided surgery.International journal of computer assisted radiology and surgery · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Solène DietschWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, W1W 7EJ, UK. solene.dietsch.20@ucl.ac.uk.
Harry AllanDepartment of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK.
Lukas LindenrothSchool of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EU, UK.
Robert MossDepartment of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK.
Agostino StilliWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, W1W 7EJ, UK.
Danail StoyanovWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, W1W 7EJ, UK.

Funding

Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS) [203145/Z/16/Z]Wellcome Trust
6 · The paper itself

Abstract

This paper presents the development of a novel X-ray detector composed of silicone elastomer and GOS:Tb, which we refer to as imaging skins. These detectors were integrated into a custom X-ray system to convert radiation into visible light. Our study focused on how fabrication parameters such as thickness and concentration impact sensor linearity, considering their potential application directly on the skin or organs to identify tumour margins during surgery. In addition, we examined how the stretching capabilities of these detectors influenced the image quality. Our imaging detection stack demonstrated consistent linearity across various fabrication parameters with the coefficient of determination ([Formula: see text]) more than 0.99998, showing that the silicone elastomer does not affect the conversion of the X-ray into light. We achieved a spatial resolution of 1.16-1.42 lp/mm at 10% of the Spatial Frequency Response using a 0.5-mm thick sensor. This study represents a first step towards integrating stretchable X-ray detectors into clinical settings, particularly on curved surfaces, to unlock their full potential in complex surgical configurations. It also highlights the need for a deeper understanding of the interactions between X-rays and detector materials to fully interpret the observed effects.

Indexed as

NeoplasmsSkinEquipment DesignHumansPhantoms, ImagingSilicone ElastomersX-RaysSilicone ElastomersImage qualityScintillatorSoft materialsStretchable sensorX-ray detector

Identifiers

PMID40211008
PMCPMC11985977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.