ArticleAnnals of biomedical engineering2025
In Vitro Assessment and Comparison of a Novel Electromagnetic Tracking System for Stereotactic DBS Surgery.
Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 synthesis or guideline pooled it.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Real-time guidance for the implantation of deep-brain-stimulation (DBS) electrodes in the context of stereotactic neurosurgery is essential but currently unavailable. Electromagnetic tracking (EMT) systems offer high-accuracy localization of tools in restricted volumes but face compatibility issues with stereotactic procedures due to electromagnetic distortions. This paper aims to evaluate and compare the localization performance (position and orientation) of a novel EMT system, the ManaDBS, specifically designed for stereotactic surgical environments, against the NDI Aurora, a commercially available EMT system. Two studies were conducted to assess the suitability of each EMT system for stereotactic DBS surgery. The first study evaluated performance accuracy within the measurement volume in the presence of two different stereotactic systems (Frame G and Vantage system, Elekta). The second study simulated a DBS surgical theater, performing implantation procedures with each EMT system and evaluating the position accuracy of the EMT sensor. The localization errors of Aurora (0.66 mm and 0.89°) were lower to those of ManaDBS (1.57 mm and 1.01°). However, in the presence of a stereotactic system, Aurora exhibited notable degradation (2.34 mm and 1.03°), whereas ManaDBS remained unaffected. This pattern persisted during simulated implantation in a DBS surgical environment, where nonlinear trajectories with significant error fluctuations along the implantation path were observed with Aurora system. The significant electromagnetic-field distortions render the Aurora system incompatible for stereotactic DBS surgery. However, the ManaDBS system exhibited no impact from these distortions, suggesting its potential suitability for DBS surgery and other potential applications in stereotactic neurosurgery.