ArticleAnnals of biomedical engineering2025

In Vitro Assessment and Comparison of a Novel Electromagnetic Tracking System for Stereotactic DBS Surgery.

Céline Vergne, Morgan Madec, Raphael Guzman, Joris Pascal, Ethan Taub, Frédéric Bourgeois, Simone Hemm

Abstract readComparative Study
In one paragraph

Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Céline VergneSchool of Life Sciences, Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland. celine.vergne@fhnw.ch.ORCID http://orcid.org/0000-0002-6412-2934
Morgan MadecICube Laboratory, University of Strasbourg-CNRS, Strasbourg, France.
Raphael GuzmanDepartment of Biomedical Engineering, Faculty of Medicine, University Basel, Allschwil, Switzerland.
Joris PascalSchool of Life Sciences, Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.
Ethan TaubDepartment of Neurosurgery, University Hospital Basel, Basel, Switzerland.
Frédéric BourgeoisSchool of Life Sciences, Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.
Simone HemmSchool of Life Sciences, Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 204448
6 · The paper itself

Abstract

Real-time guidance for the implantation of deep-brain-stimulation (DBS) electrodes in the context of stereotactic neurosurgery is essential but currently unavailable. Electromagnetic tracking (EMT) systems offer high-accuracy localization of tools in restricted volumes but face compatibility issues with stereotactic procedures due to electromagnetic distortions. This paper aims to evaluate and compare the localization performance (position and orientation) of a novel EMT system, the ManaDBS, specifically designed for stereotactic surgical environments, against the NDI Aurora, a commercially available EMT system. Two studies were conducted to assess the suitability of each EMT system for stereotactic DBS surgery. The first study evaluated performance accuracy within the measurement volume in the presence of two different stereotactic systems (Frame G and Vantage system, Elekta). The second study simulated a DBS surgical theater, performing implantation procedures with each EMT system and evaluating the position accuracy of the EMT sensor. The localization errors of Aurora (0.66 mm and 0.89°) were lower to those of ManaDBS (1.57 mm and 1.01°). However, in the presence of a stereotactic system, Aurora exhibited notable degradation (2.34 mm and 1.03°), whereas ManaDBS remained unaffected. This pattern persisted during simulated implantation in a DBS surgical environment, where nonlinear trajectories with significant error fluctuations along the implantation path were observed with Aurora system. The significant electromagnetic-field distortions render the Aurora system incompatible for stereotactic DBS surgery. However, the ManaDBS system exhibited no impact from these distortions, suggesting its potential suitability for DBS surgery and other potential applications in stereotactic neurosurgery.

Indexed as

Deep Brain StimulationStereotaxic TechniquesElectromagnetic PhenomenaHumansDeep brain stimulationElectromagnetic trackingInterventional guidanceStereotactic neurosurgerySystem assessment

Identifiers

PMID40208399
PMCPMC12075333

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.