Respiratory Motion Effects and Mitigation Strategies on Boiling Histotripsy in Porcine Liver and Kidney.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Review
- Doppler-based assessment of boiling histotripsy-induced volumetric tissue liquefaction in vivo.Ultrasonics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Boiling histotripsy (BH) is a pulsed high-intensity focused ultrasound (HIFU)-based method of extracorporeal nonthermal tissue disintegration under real-time ultrasound (US) guidance. Respiratory motion in abdominal targets can affect BH precision and completeness. This study compares two motion mitigation strategies based on pulse/echo US motion tracking: robotic arm-based unidirectional motion compensation by HIFU transducer manipulation and BH pulse gating during expiratory pause. BH ablations were generated in the liver and kidney of anesthetized pigs with 2-10-ms pulses using a 256-element 1.5-MHz HIFU array. A coaxial US imaging probe was used for targeting, tracking skin surface, and monitoring real-time bubble activity. The axial [anterior-posterior (AP)] displacement of the skin surface was found to be synchronous with liver and kidney motion in both cranio-caudal (CC) and AP directions. BH lesions were produced either with no motion mitigation, or with pulse gating, or with 1-D motion compensation. Dimensions of completely fractionated and affected tissue areas were measured histologically. In liver, gating and motion compensation improved fractionation completeness within targeted volumes and reduced off-target tissue damage in AP direction versus no motion mitigation; only gating reduced off-target damage in CC direction. In kidney, gating improved BH completeness in both directions versus no mitigation, but did not affect off-target damage due to lower displacement amplitudes in the kidney comparable with gating tolerance limits. In both liver and kidney, gating increased treatment time by 24%. These results suggest that BH pulse gating using US-based AP skin surface tracking is an adequate approach for treating organs with pronounced 3-D respiratory motion.