Evidence map›Paper›PMID 40201911›Full record

ReviewIndian journal of orthopaedics2025

Implant Design and Its Applications in the Fixation of Osteoporotic Bones: Newer Technologies in Nails, Plates and External Fixators.

Srinivas B S Kambhampati, Senthilvelan Rajagopalan, Vineet Thomas Abraham, Murali Poduval, Lalit Maini

Abstract readReview
In one paragraph

Review in Indian journal of orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. [Application of minimally invasive techniques in clinical treatment of tibial plateau fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Srinivas B S KambhampatiSri Dhaatri Orthopaedic, Maternity and Gynaecology Center, SKDGOC, Vijayawada, Andhra Pradesh 531127 India.ORCID 0000-0002-4978-3590
Senthilvelan RajagopalanDepartment of Shoulder and Upper Limb Surgery, MIOT International, Chennai, 600089 India.
Vineet Thomas AbrahamDepartment of Orthopedics, AIIMS Mangalagiri, Guntur, Andhra Pradesh 522503 India.
Murali PoduvalLife Sciences Engineering, Tata Consultancy Services, Mumbai, India.
Lalit MainiDepartment of Orthopaedics, Maulana Azad Medical College, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Osteoporosis, characterised by decreased bone mass and degradation of bone tissue, poses a major global health concern, particularly for the ageing population. The traditional fixation techniques often fail in osteoporotic bones due to their diminished density and strength. Technological advancements in orthopaedic implants, specifically nails, plates, and external fixators, have emerged to address these challenges. Materials and Methods: Improvements in implant design focus on material properties, surface modifications, and geometric advancements. Titanium and its alloys are favoured for their biomechanical properties such as lower elastic modulus and high strength-to-weight ratio. The biodegradable materials like polylactic acid and magnesium alloys offer the advantage of gradual resorption as bone heals. Surface modifications, such as coatings with bioactive materials and drug-eluting surfaces, promote osseointegration and enhance fixation strength. Results and Discussion: Intramedullary (IM) nails have evolved to enhance stability and minimise complications associated with osteoporotic fractures. Third and fourth-generation nails incorporate surface treatments for better integration and healing. The advances in screw design, locking mechanisms, and flexible axial stimulation have improved fixation and allowed micromotion, which promotes fracture healing. The use of external fixators, particularly for complex fractures in osteoporotic bones, offers less invasive treatment options with adaptable stiffness for improved healing. Conclusion: Technological innovations in implant materials, design, and surgical techniques have significantly improved the management of osteoporotic fractures. Newer technologies, including 3D printing, virtual and augmented reality, and artificial intelligence, show promise in enhancing implant customization, surgical planning, and postoperative outcomes. However, further clinical validation and research are needed to expand their clinical applications.

Indexed as

Implant designsNewer technologyOsteoporosisRecent advances

Identifiers