Evidence map›Paper›PMID 40200410›Full record

ArticleClinical implant dentistry and related research2025

Impact of High Insertion Torque on Implant Surface Integrity.

Cindy Dodo, Plinio Mendes Senna, Altair Antoninha Del Bel Cury, Luiz Meirelles

Abstract read
In one paragraph

Article in Clinical implant dentistry and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Cindy DodoDepartment of General Dental Sciences, School of Dentistry, Marquette University, Milwaukee, Wisconsin, USA.
Plinio Mendes SennaDepartment of Prosthodontics, School of Dentistry, Rio de Janeiro State University, Rio de Janeiro, Brazil.
Altair Antoninha Del Bel CuryDepartment of Prosthodontics and Periodontics, Piracicaba School of Dentistry, State University of Campinas, Piracicaba, Brazil.
Luiz MeirellesDivision of Restorative and Prosthetic Dentistry, College of Dentistry, the Ohio State University, Columbus, Ohio, USA.ORCID https://orcid.org/0000-0002-6840-5210

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe long-term success of dental implants depends on the preservation of supporting tissues over time. Recent studies have highlighted the release of titanium particles as a potential etiology for the onset and progression of peri-implant diseases modulated by inflammatory biomarkers. This study provides a comprehensive analysis of surface changes associated with high insertion torque placement.

methodsThree groups of cylindrical threaded dental implants, each representing different surface topographies produced by anodization or a combination of grit-blasting and acid-etching processes, were inserted into fresh cow rib bone blocks used to mimic human jaws. Individual bone blocks were fabricated with a dimension of 20 × 15 × 15 mm, randomly assigned to the three implant groups. Prior to dental implant placement, the bone blocks were divided in half to facilitate implant removal without introducing additional damage. The drilling protocol was modified, excluding the final drill recommended by the manufacturer to ensure higher insertion torque values during the procedure. Dental implants were removed from the bone blocks and processed for analysis. Surface roughness was characterized using interferometry on the same area before and after insertion. Scanning electron microscopy (SEM) with a back-scattered electron detector (BSD) was employed to identify the implant surface and loose particles at the bone block interface.

resultsThe high insertion torque protocol used in this study resulted in higher insertion torque values compared to manufacturers' protocol, but no difference was observed when comparing the three implant groups. Surface roughness characterization revealed that amplitude and hybrid roughness parameters for all three groups were lower after insertion. The surfaces exhibiting a predominance of peaks (Ssk [skewness] > 0) associated with higher structures (height parameters) showed greater damage at the crests of the threads, while no changes were observed in the valleys of the threads. SEM-BSD images revealed loose titanium particles at the bone blocks interface, predominantly at the crestal cortical bone level.

conclusionsHigh insertion torque resulted in surface damage at the crests of threads, which subsequently led to the release of titanium particles primarily at the bone crest. The initial release of titanium particles during implant insertion at the bone-implant interface warrants further exploration as a potential cofactor for marginal bone loss.

Indexed as

Dental Implantation, EndosseousDental ImplantsTorqueAnimalsCattleDental Prosthesis DesignMicroscopy, Electron, ScanningSurface PropertiesTitaniumDental ImplantsTitaniumbiomaterialsimplant designimplant surfacesurface propertiessurface topography

Identifiers

PMID40200410
PMCPMC11978974

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.