Evidence map›Paper›PMID 40199928›Full record

ArticleScientific reports2025

Transcranial brain-wide functional ultrasound and ultrasound localization microscopy in mice using multi-array probes.

Mathis Vert, Ge Zhang, Adrien Bertolo, Nathalie Ialy-Radio, Sophie Pezet, Bruno Osmanski, Thomas Deffieux, Mohamed Nouhoum, Mickael Tanter

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Assessing cerebral capillary function and stalling using single capillary reporters in ultrasound localization microscopy.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mathis Vert *Physics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Ge Zhang *Physics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Adrien BertoloPhysics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Nathalie Ialy-RadioPhysics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Sophie PezetPhysics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Bruno OsmanskiIconeus, Paris, France.
Thomas DeffieuxPhysics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Mohamed Nouhoum *Iconeus, Paris, France.
Mickael Tanter *Physics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France. mickael.tanter@espci.fr.

Funding

Agence Nationale de la Recherche ANR-21-CE19-0050European Union's Horizon 2020 Research and Innovation programme No 874721 PREMSTEM
6 · The paper itself

Abstract

Functional ultrasound imaging (fUS) and ultrasound localization microscopy (ULM) are advanced ultrasound imaging modalities for assessing both functional and anatomical characteristics of the brain. However, the application of these techniques at a whole-brain scale has been limited by technological challenges. While conventional linear acoustic probes provide a narrow 2D field of view and matrix probes lack sufficient sensitivity for 3D transcranial fUS, multi-array probes have been developed to combine high sensitivity to blood flow with fast 3D acquisitions. In this study, we present a novel approach for the combined implementation of transcranial whole-brain fUS and ULM in mice using a motorized multi-array probe. This technique provides high-resolution, non-invasive imaging of neurovascular dynamics across the entire brain. Our findings reveal a significant correlation between absolute cerebral blood volume (ΔCBV) increases and microbubble speed, indicating vessel-level dependency of the evoked response. However, the lack of correlation with relative CBV (rCBV) suggests that fUS cannot distinguish functional responses alterations across different arterial vascular compartments. This methodology holds promise for advancing our understanding of neurovascular coupling and could be applied in brain disease diagnostics and therapeutic monitoring.

Indexed as

BrainMicroscopyAnimalsCerebrovascular CirculationMaleMiceMice, Inbred C57BLMicrobubblesUltrasonographyUltrasonography, Doppler, TranscranialBrain imagingCerebral blood volumeFunctional ultrasound imagingMulti-array probeUltrasound localization microscopy

Identifiers

PMID40199928
PMCPMC11978944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.