Evidence map›Paper›PMID 40191388›Full record

ArticleImaging science in dentistry2025

Comparison of objective radiograph quality between radiographs obtained with wall-mounted and handheld X-ray devices.

Débora Costa Ruiz, Rocharles Cavalcante Fontenele, Amanda Farias-Gomes, Matheus L Oliveira, Deborah Queiroz Freitas, Francisco Haiter-Neto

Abstract read
In one paragraph

Article in Imaging science in dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Débora Costa RuizDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-2223-1286
Rocharles Cavalcante FonteneleOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium.ORCID https://orcid.org/0000-0002-6426-9768
Amanda Farias-GomesDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-4707-4838
Matheus L OliveiraDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-8054-8759
Deborah Queiroz FreitasDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-1425-5966
Francisco Haiter-NetoDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-5610-8307

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study was conducted to compare the objective image quality of radiographs acquired with a handheld X-ray device to those obtained with a wall-mounted X-ray device. Materials and Methods: Brightness, noise, uniformity, and contrast were evaluated. To assess the first 3 parameters, radiographs of an acrylic block were acquired with an unused photostimulable phosphor (PSP) plate from the VistaScan system (Mini Easy, Dürr Dental, Bietigheim-Bissingen, Germany). Initially, 6 radiographs were taken with a Focus X-ray wall-mounted device (Instrumentarium, Tuusula, Finland) operating at 60 kVp, 7 mA, and 0.125 s. Another 6 radiographs were captured using an Eagle handheld X-ray device (Alliage, São Paulo, Brazil) at 60 kVp, 2.5 mA, and 0.35 s. The means and standard deviations of the gray values for all radiographs were calculated using ImageJ (National Institutes of Health, Bethesda, MD, USA). For contrast assessment, radiographs of an aluminum step wedge were obtained using the same PSP plate, X-ray devices, and acquisition parameters. The percentage of contrast variation was determined. The impacts of the devices on image quality were compared using the Student Results: Compared with the wall-mounted device, the handheld device produced radiographs with higher brightness and noise, as indicated by mean values of 6.57 (0.49) and 3.49 (0.02), respectively. Furthermore, it demonstrated lower uniformity and contrast, with respective means of 3.75 (0.02) and 35.48 (0.09) ( Conclusion: Radiographs obtained using a handheld X-ray device exhibit lower theoretical image quality than those acquired with a wall-mounted device.

Indexed as

Dental Digital RadiographyQuality ControlRadiographyX-rays

Identifiers

PMID40191388
PMCPMC11966020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.