Evidence map›Paper›PMID 40190466›Full record

ArticleFrontiers in cardiovascular medicine2025

Early experience with a novel transapical transcatheter aortic valve system in patients with severe aortic stenosis: a prospective, multicenter study.

Lulu Liu, Jian Yang, Haibo Zhang, Jian Liu, Yucheng Zhong, Lai Wei, Xianbao Liu, Zhao Jian, Yuan Zhao, Yingqiang Guo

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lulu LiuDepartment of Cardiovascular Surgery, West China Hospital, Chengdu, China.
Jian YangDepartment of Cardiac Surgery, Xijing Hospital, Xi'an, China.
Haibo ZhangDepartment of Cardiac Surgery, Beijing Anzhen Hospital, Beijing, China.
Jian LiuDepartment of Cardiac Surgery, Guangdong Provincial People's Hospital, Guangzhou, China.
Yucheng ZhongDepartment of Cardiovascular Medicine, Wuhan Union Hospital, Wuhan, China.
Lai WeiDepartment of Cardiac Surgery, Shanghai Zhongshan Hospital, Shanghai, China.
Xianbao LiuDepartment of Cardiovascular Medicine, The Second Affiliated Hospital of Zhejiang University, Hangzhou, China.
Zhao JianDepartment of Cardiac Surgery, Xinqiao Hospital, Chongqing, China.
Yuan ZhaoDepartment of Cardiac Surgery, The Second Xiangya Hospital of Central South University, Changsha, China.
Yingqiang GuoDepartment of Cardiovascular Surgery, West China Hospital, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Registered, prospective, multicenter study of the short-term clinical outcomes of a novel transcatheter aortic valve system (Xcor system, Saint Medical Technology, Inc., Nanjing) to evaluate its safety and efficacy. Methods: 130 high risk patients with symptomatic severe AS from 11 institutions were treated with the novel Xcor system. All patients were pre-TAVR assessed by transthoracic echocardiography and computed tomography of the aortic valve (AV) and relevant left cardiac and vascular anatomy. Procedural, in-hospital, and follow-up clinical outcomes were evaluated after procedures. Results: The average age of the 130 patients was 71.2 ± 4.4 years old, 55.4% were male, and the STS score was 8.0 ± 3.9%. Device and procedural success were achieved in 98.5% and 97.7% of the patients, respectively. At 30-day follow-up, all-cause mortality, the incidence of major adverse cardiovascular events, major vascular complications, and new permanent pacemaker implantation were 3.8%, 4.6%, 0.8%, and 0.8%, respectively. 7.7% of patients showed ≥ mild paravalvular leakage, and all 125 (100%) patients were in New York Heart Association Class ≤ II. The procedural and clinical outcomes of bicuspid AV patients were similar to those of tricuspid AV patients. Conclusions: Overall, the 30-day follow-up shows that the procedural outcomes with the novel Xcor system with self-centering support arms are comparable or superior to other contemporary TAVI devices, with a low all-cause mortality, low major adverse cardiovascular events, low PVL and similar clinical outcomes for BAV and TAV patients.

Indexed as

aortic stenosissupporting armtransapicaltranscatheter aortic valve replacementXcor transcatheter heart valve system

Identifiers

PMID40190466
PMCPMC11968724

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked