ArticleInternational journal of computer assisted radiology and surgery2025
Parametric-MAA: fast, object-centric avoidance of metal artifacts for intraoperative CBCT.
Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeMetal artifacts remain a persistent issue in intraoperative CBCT imaging. Particularly in orthopedic and trauma applications, these artifacts obstruct clinically relevant areas around the implant, reducing the modality's clinical value. Metal artifact avoidance (MAA) methods have shown potential to improve image quality through trajectory adjustments, but often fail in clinical practice due to their focus on irrelevant objects and high computational demands. To address these limitations, we introduce the novel parametric metal artifact avoidance (P-MAA) method.
methodsThe P-MAA method first detects keypoints in two scout views using a deep learning model. These keypoints are used to model each clinically relevant object as an ellipsoid, capturing its position, extent, and orientation. We hypothesize that fine details of object shapes are less critical for artifact reduction. Based on these ellipsoidal representations, we devise a computationally efficient metric for scoring view trajectories, enabling fast, CPU-based optimization. A detection model for object localization was trained using both simulated and real data and validated on real clinical cases. The scoring method was benchmarked against a raytracing-based approach.
resultsThe trained detection model achieved a mean average recall of 0.78, demonstrating generalizability to unseen clinical cases. The ellipsoid-based scoring method closely approximated results using raytracing and was effective in complex clinical scenarios. Additionally, the ellipsoid method provided a 33-fold increase in speed, without the need for GPU acceleration.
conclusionThe P-MAA approach provides a feasible solution for metal artifact avoidance in CBCT imaging, enabling fast trajectory optimization while focusing on clinically relevant objects. This method represents a significant step toward practical intraoperative implementation of MAA techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.