The effect of post-polymerization methods and varying thicknesses on colour stability and flextural strength of denture base polymers produced with stereolithography (SLA) technique.

Esra Kul, Saba Ostovar, Seyhan Kahraman, Nuran Yanıkoğlu, Faruk Yeşildal

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Esra KulDepartment of Prosthetic Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey. esra.kul@atauni.edu.tr.
Saba OstovarDepartment of Prosthetic Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey.
Seyhan KahramanDepartment of Prosthetic Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey.
Nuran YanıkoğluDepartment of Prosthetic Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey.
Faruk YeşildalDepartmet of Energy, Faculty of Engineering, Ataturk University, Erzurum, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLimited information is available on the thickness and post-polymerization procedure of denture base resins produced by stereolithography (SLA). This study aims to assess the impact of varying thickness, post-curing durations, and temperature on the flexural strength and colour stability of 3D-printed denture bases. MATERIALS AND

methodsA total of 80 rectangular specimens, measuring 65 × 10 × 3 mm and 65 × 10 × 2 mm, were developed using 3D-printed acrylic resin. The 3D-printed groups were further categorised based on their thickness into two groups: 2 mm and 3 mm. Each of these four groups was then subdivided based on the post-curing temperature (60 °C and 80 °C) and post-curing duration (15 min and 60 min). To ensure colour stability, the specimens were placed in an incubator containing a coffee solution at a temperature of 37 degrees Celsius. To evaluate the flexural strength of the specimens, they were placed on a specialised jig with two supports that were 50 mm apart. The jig was securely attached to a universal testing machine. The spectrophotometer was used to measure the colour changes (ΔE00) of the specimens that underwent different post-curing procedures and were immersed in coffee. The data analysis involved the use of ANOVA and Tukey's post hoc tests, with a significance level (α) set at 0.05.

resultsThe study's findings suggest that the flexural strength values exhibited an upward trend as the post-curing periods increased from 15 to 60 min and the temperatures rose from 40 °C to 80 °C. Group 2 and 4 showed the highest flexural strength (86 MPa and 95 MPa, respectively). Group 2 with less thickness than group 4 exhibited a better color stability and acceptable level of color change with ΔΕ00 = 2.59.

conclusionsThe study revealed that the specimens with a thickness of 3 mm, a post-curing period of 60 min, and a temperature of 80 °C exhibited the best flexural strength but the lowest colour stability compared to the other groups. Optimum results can be achieved by increasing the post polymerization time and temperature rather than increasing the thickness of the denture base. Because group 2, which has a thickness of 2 mm and is subjected to the same post-curing period, has acceptable clinical results in terms of both flexural strength and color stability. CLINICAL TRIAL NUMBER: Not applicable.

Indexed as

Acrylic ResinsDenture BasesFlexural StrengthPolymersStereolithographyColorDental Stress AnalysisHumansMaterials TestingPolymerizationPrinting, Three-DimensionalTemperatureAcrylic ResinsPolymersCAD/CAMDenture basePost-polymerizationSLAThickness

Identifiers

PMID40186191
PMCPMC11969955

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.