Evidence map›Paper›PMID 40186165›Full record

ArticleBMC surgery2025

Patient-specific instrumentation technology enhances clinical outcomes in total elbow arthroplasty.

Changgui Zhang, Hongquan Heng, Shu Deng, Xin Chen, Guangxing Chen, Hao Chen

Abstract read
In one paragraph

Article in BMC surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Changgui Zhang *Center for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China.
Hongquan Heng *Center for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China.
Shu Deng *Center for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China.
Xin ChenCenter for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China.
Guangxing ChenCenter for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China. cgx7676@tmmu.edu.cn.
Hao ChenCenter for Joint Surgery, Intelligent Manufacturing and Rehabilitation Engineering Center, The First Affiliated Hospital of Army Medical University, Chongqing, 400038, China. beyondest@tmmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate and compare the outcomes of utilizing patient-specific instrumentation (PSI) technology, which incorporates personalized three-dimensional (3D) preoperative planning and customized 3D printing (3DP) osteotomy guides, against those achieved with traditional instruments in total elbow arthroplasty (TEA).

methodsA retrospective study was conducted to analyze the clinical data of 20 patients diagnosed with elbow arthritis who underwent TEA at the Center for Joint Surgery, The First Hospital Affiliated to Army Medical University, China, between January 2010 and July 2023. Patients were categorized into two groups according to the surgical techniques employed: 9 patients underwent personalized preoperative 3D planning and used customized 3DP osteotomy guides for TEA (3DP group); another 11 patients underwent TEA using traditional instruments and experience-based techniques (traditional group). The intraoperative fluoroscopy frequency, Mayo elbow performance score (MEPS), and Mayo elbow score before and after surgery in both groups were recorded. Additionally, in the 3DP group, changes in the imaging indicators such as the angle between the axis of humerus medullary cavity and the hinge axis of elbow (H-H angle), the angle between the axis of middle ulna medullary cavity and the hinge axis of elbow (MU-H angle), the angle between the axis of proximal ulna medullary cavity and the hinge axis of elbow (PU-H angle) were assessed before and after surgery.

resultsNo significant differences were observed in the baseline characteristics between the 3DP group and the traditional group (P > 0.05). We followed all patients for a period ranging from 12 to 36 months, with an average follow-up duration of 14.8 months. When comparing the two groups, the 3DP group required fewer intraoperative fluoroscopic view (P < 0.01). Postoperatively, the 3DP group showed notable improvements in the H-H angle, MU-H angle, and PU-H angle, all of which were significantly better than those in the traditional group (P < 0.01). Despite these advantages, the postoperative MEPS and Mayo elbow function scores did not differ significantly between the 3DP and traditional groups (P > 0.05).

conclusionCompared with traditional surgical methods, the use of PSI technology with preoperative 3D planning and customized 3DP osteotomy guides can significantly reduce the number of intraoperative fluoroscopies, which enhances both the efficiency and safety of TEA. PSI technology facilitates more accurate angle correction during elbow arthroplasty, ensuring precise osteotomies and effective correction of joint deformities.

Indexed as

Arthroplasty, Replacement, ElbowElbow JointPrinting, Three-DimensionalAdultAgedFemaleHumansMaleMiddle AgedOsteotomyRetrospective StudiesTreatment Outcome3D-printed personalized guidesElbow arthritisElbow arthroplastyThree-dimensional reconstruction

Identifiers

PMID40186165
PMCPMC11969954

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.