Evidence map›Paper›PMID 40185938›Full record

ArticlePediatric cardiology2026

Konar-MF ™: Versatile Utility Suggests Potential to Simplify Congenital Catheterization Laboratory Inventory.

Navaneetha Sasikumar, Pranoti Toshniwal, Usha Mandikal Kondakarna Sastry, Shweta Bakhru, Jayaranganath Mahimarangaiah, Nageshwara Rao Koneti, Raman Krishna Kumar

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Navaneetha SasikumarDepartment of Pediatric Cardiology, Amrita Institute of Medical Sciences, Ponekkara, Kochi, Kerala, 682041, India. drnavni@yahoo.com.
Pranoti ToshniwalDepartment of Pediatric Cardiology, Amrita Institute of Medical Sciences, Ponekkara, Kochi, Kerala, 682041, India.
Usha Mandikal Kondakarna SastryDepartment of Pediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Jayanagar 9th Block, Bannerghatta Road, Bangalore, Karnataka, 560 069, India.
Shweta BakhruDepartment of Pediatric Cardiology, Rainbow Children'S Hospital, Banjara Hills, Hyderabad, Telangana, 500034, India.
Jayaranganath MahimarangaiahDepartment of Pediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Jayanagar 9th Block, Bannerghatta Road, Bangalore, Karnataka, 560 069, India.
Nageshwara Rao KonetiDepartment of Pediatric Cardiology, Rainbow Children'S Hospital, Banjara Hills, Hyderabad, Telangana, 500034, India.
Raman Krishna KumarDepartment of Pediatric Cardiology, Amrita Institute of Medical Sciences, Ponekkara, Kochi, Kerala, 682041, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

KONAR-MF™ device is a novel, cone-shaped, medium profile, self-expanding, double-disk, nitinol occlusive device designed for the ventricular septal defect (VSD). Due to its unique design and easy deployment from either side and multiple occlusion layers, it has also been used to occlude defects other than VSD. A retrospective review was done from 2019 to 2024 from three institutions. All patients where the KONAR-MF™ device was used other than for VSD closure were included in this study. Standard post-procedure follow-up was at 1, 6, and 12 months for all patients. 79 off-label implantations of the KONAR-MF™ device were done for conditions that included 59 shunt lesions (patent ductus arteriosus -34, coronary arteriovenous fistula -12, pulmonary arteriovenous fistula -2, systemic arteriovenous fistula -3, aortopulmonary window -3, aortopulmonary collateral -5, Fontan fenestration closures -7, Fontan antegrade pulmonary valve closures -2, Abernethy malformations -3, decompressing vein -2, and paravalvular leak -2, others 4. The median fluoroscopy time was 10 min (IQR 6-18). The median duration of hospital stay was 2 days (IQR 1-4 days). There were no significant complications. Complete occlusion at the end of the procedure was documented in 72 (91.13%) patients. At a median follow-up of 18 months (IQR 12-28 months) in all except one patient who had mild residual flow with no device-/(procedure) related complications. The unique structure and compact profile of KONAR-MF™ enable a wide range of uses in catheter-based management of various CHDs with the potential to simplify the inventory of the catheterization laboratory.

Indexed as

Cardiac CatheterizationHeart Defects, CongenitalHeart Septal Defects, VentricularSeptal Occluder DeviceChildChild, PreschoolEquipment DesignFemaleFollow-Up StudiesHumansInfantMaleRetrospective StudiesCongenital heart diseaseDevice closureTrans catheter closure

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.