Evidence map›Paper›PMID 40184607›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2025

Chronic, Battery-Free, Fully Implantable Multimodal Spinal Cord Stimulator for Pain Modulation in Small Animal Models.

Allie J Widman, Taron Bashar, Alex Burton, David Marshall Clausen, Prashant Gupta, Drew K Wolf, Jakayla Folarin-Hines, Maria Payne, John A Rogers, Kathleen W Meacham and 2 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Implantable bioelectronic outlet.Science advances · 2026
    Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Allie J WidmanDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.ORCID https://orcid.org/0000-0002-0425-7853
Taron BasharDepartment of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.ORCID https://orcid.org/0009-0009-4729-5436
Alex BurtonDepartment of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.ORCID https://orcid.org/0000-0001-7182-0696
David Marshall ClausenDepartment of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.ORCID https://orcid.org/0000-0002-3566-1859
Prashant GuptaDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.
Drew K WolfDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.
Jakayla Folarin-HinesDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.
Maria PayneDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.
John A RogersDepartment of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.ORCID https://orcid.org/0000-0002-2980-3961
Kathleen W MeachamDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.
Robert W GereauDepartment of Anesthesiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.ORCID https://orcid.org/0000-0002-5428-4251
Philipp GutrufDepartment of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.ORCID https://orcid.org/0000-0002-7183-7268

Funding

TRAINING PROGRAM IN ANESTHESIOLOGY RESEARCHT32GM108539 · NIGMS · WASHINGTON UNIVERSITY · PI Aaron J Norris · 2014 to 2026
$4.9M
Gordon and Betty Moore FoundationInternational Anesthesia Research SocietyNIGMS NIH HHS T32 GM108539
6 · The paper itself

Abstract

Spinal cord stimulation (SCS) for chronic pain management is an invasive therapy involving surgical implantation of electrodes into spinal epidural space. While the clinical value and mechanistic action of the therapy is debated considerably in recent years, preclinical chronic studies employing rodent models can provide invaluable insights regarding the balance between efficacy and complications as well as mechanistic understanding of SCS therapy. However, current rodent compatible devices require tethered power delivery or bulky batteries, severely limiting the ability to probe long-term efficacy of SCS therapy. This work introduces a tether-free, small-footprint, fully implantable, battery-free SCS device compatible with rodent models, capable of delivering electrical stimulation to the spinal cord at a wide range of frequency, amplitude, and period via wireless communication adjustable on-demand without direct interaction with the animal. The presented device features capabilities of clinical SCS devices, with materials and processes amendable to scalable fabrication at a cost suitable for one-time use enabling high N studies. In this proof of concept, the implantable device serves to assess therapeutic efficacy of various clinically relevant SCS paradigms in alleviating neuropathic pain. This technology offers chronic stability and the potential to serve as the foundation for future research into the development of SCS therapeutic systems.

Indexed as

Chronic PainNeuralgiaPain ManagementSpinal Cord StimulationAnimalsDisease Models, AnimalElectrodes, ImplantedRatsSpinal Cordchronic painneuromodulationpain modulationpreclinical modelsspinal cord stimulatorwireless implants

Identifiers

PMID40184607
PMCPMC12140358

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.