Evidence map›Paper›PMID 40182912›Full record

ArticleInternational journal of sports physical therapy2025

Reliability of Hand-Held Dynamometer in Measuring Gluteal Muscle Rate of Torque Development and Peak Torque: Push and Pull Configurations.

Takhyun Yoo, Sungwan Kim, Julie P Burland, Neal R Glaviano

Abstract read
In one paragraph

Article in International journal of sports physical therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Takhyun YooKinesiology University of Connecticut.
Sungwan KimKinesiology University of Connecticut.
Julie P BurlandKinesiology University of Connecticut.
Neal R GlavianoKinesiology University of Connecticut.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Belt-stabilized handheld dynamometers (HHD) assess hip rate of torque development (RTD) and strength in research and clinical practice. However, the reliability of HHD with push and pull configurations to measure hip muscles RTD and peak torque is unclear. Purpose/Hypothesis: To determine the intra- and inter-reliability of HHD utilizing push and pull configurations to measure hip abduction and extension early (0-100ms) and late (100-200ms) phases RTD and peak torque. We hypothesized HHD with both configurations would be reliable for measuring hip extension and abduction RTD and peak torque. Study Design: Cross-sectional study. Methods: Twenty healthy adults (10 females) performed three consecutive maximal isometric contraction trials of hip abduction and extension, utilizing an HHD with push and pull configurations by two raters. Each rater's average early and late phases RTD and peak torque of hip abduction and extension were utilized for analysis. Results: Intra-rater reliability of hip abduction with push and pull configurations ranged moderate-to-good for early and late RTD phases (push: ICC2,1=0.61-0.88; pull: ICC2,1=0.59-0.75). Peak hip abduction torque showed good reliability in both configurations (ICC2,1≥0.79). Hip extension ranged moderate-to-good reliability for early and late RTD phases in push configuration (ICC2,1=0.72-0.87), with good-to-excellent reliability in pull (ICC2,1=0.77-0.91). Peak hip extension torque showed moderate-to-excellent reliability for push configuration (ICC2,1=0.73-0.92) and excellent reliability for pull (ICC2,1≥0.91). Inter-rater reliability for hip abduction showed moderate in push (ICC3,k≥0.72) and good in pull (ICC3,k≥0.78) configurations for both RTD phases, while hip extension showed good reliability in push (ICC3,k≥0.82) and excellent reliability in pull (ICC3,k≥0.95) configurations. Peak torque showed good reliability for hip abduction (ICC3,k≥0.83) and excellent reliability for extension (ICC3,k≥0.94) in both configurations. Conclusions: HHD with push and pull configurations is a reliable and cost-effective method for assessing RTD and strength of hip abductors and extensors in healthy adults. Level of Evidence: Level 3.

Indexed as

Hand-held DynamometerHip MuscleNeuromuscular FunctionReproducibility

Identifiers

PMID40182912
PMCPMC11964699

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.