Evidence map›Paper›PMID 40182343›Full record

ArticleCureus2025

Evaluation of Gastric Conduit Perfusion Using Indocyanine Green Fluorescence During Radical Esophagectomy and Its Correlation With Anastomotic Leak: A Single-Center, Prospective Study.

Lijin Selvens, Suraj Surendran, Vijay P Abraham, Negine Paul, Samuel Paul Dhinakar Arelly, Yacob Myla, Inian Samarasam

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lijin SelvensDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.
Suraj SurendranDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.
Vijay P AbrahamDepartment of Surgery, The Queen Elizabeth Hospital, Woodville South, AUS.
Negine PaulDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.
Samuel Paul Dhinakar ArellyDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.
Yacob MylaDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.
Inian SamarasamDepartment of General and Upper Gastrointestinal Surgery, Christian Medical College, Vellore, Vellore, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Anastomotic leak (AL) is a leading cause of morbidity after esophagectomy, with gastric conduit perfusion being a key predictor. The perfusion of the gastric conduit is often analyzed subjectively based on visual inspection, such as the presence of bright bleeding from the resection margin, pulsation of supplying arcade vessels, and tissue color. Indocyanine Green (ICG) fluorescence is a new tool that helps objectively assess the gastric conduit's perfusion. Aim To evaluate the role of ICG fluorescence in assessing gastric conduit perfusion and its correlation with AL. Methods This single-center prospective study from a tertiary hospital in South Asia included patients with esophageal cancer undergoing esophagectomy from December 2019 to December 2021. Gastric conduit perfusion was assessed using real-time ICG imaging with a near-infrared ICG camera (KARL STORZ® SE & Co. KG, Tuttlingen, Germany). It was done before and after trans-mediastinal pull-up and compared with visual perfusion assessment. AL was monitored for two weeks postoperatively. Results Sixteen patients (Male, 50%; mean age 53.7 years; squamous carcinoma, 81.2%; stage III-IVA, 50%; neoadjuvant treatment, 100%) undergoing minimally invasive esophagectomy (14 McKeown's, 2 Ivor Lewis) were included. Before and after the trans-mediastinal pull-up, visual assessment revealed "good" perfusion in 15 and 14 patients, respectively. However, according to the ICG-based evaluation, "good" perfusion was seen in just eight and two patients, respectively. Several conduits showing "good" visual perfusion exhibited "sluggish" perfusion on ICG fluorescence. One patient required conduit tip resection due to "poor" ICG perfusion despite a "good" visual assessment. Two patients (13.3%) developed AL, both of whom belonged to a group of five patients with a change in the ICG perfusion pattern of the gastric conduit from "good" to "sluggish" after its trans-mediastinal pull-up. A significant correlation (asymptotic sig. (2-tailed) P=0.022) was observed between real-time changes in the conduit's ICG perfusion speed between its abdominal and cervical positions and AL occurrence. Conclusion ICG fluorescence is a valuable tool for assessing gastric conduit perfusion during esophagectomy, identifying under-perfused conduits more accurately than visual evaluation. The time difference in perfusion speed before and after trans-mediastinal pull-up is critical, and we believe that assessing perfusion at both stages of the operation is crucial to identifying and addressing perfusion-related issues.

Indexed as

anastomotic leakesophageal carcinomaesophagectomygastric conduit perfusionindocyanine green

Identifiers

PMID40182343
PMCPMC11964882

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.