Navigation increases the accuracy of glenoid component implantation in reverse total shoulder arthroplasty in shoulders with severe glenoid wear: a comparative cohort study.

Gregory Cunningham, Andres Rodriguez Borgonovo, Miguel Rivera, Rodrigo Brandariz

Abstract read
In one paragraph

Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gregory CunninghamLa Colline Shoulder and Elbow Center, Geneva, Switzerland.
Andres Rodriguez BorgonovoLa Colline Shoulder and Elbow Center, Geneva, Switzerland.
Miguel RiveraLa Colline Shoulder and Elbow Center, Geneva, Switzerland.
Rodrigo BrandarizLa Colline Shoulder and Elbow Center, Geneva, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Indications for reverse total shoulder arthroplasty (rTSA) have increased over the years and seem to yield satisfactory functional results even in patients with severe glenoid wear. New technologies, such as navigation, have gained in popularity intending to increase implantation precision, which is a crucial factor for long-term implant survivorship. However, these technologies remain costly and their widespread use for everyday cases has yet to be determined. Objectives: This study aimed to compare the accuracy of glenoid component implantation in consecutive series of patients undergoing rTSA with and without navigation, according to the wear patterns of the glenoid. Study Design & Methods: Two consecutive series of patients operated on by the same shoulder surgeon for rTSA, with and without navigation using the NextAR system (Medacta, Castel San Pietro, Switzerland), were prospectively included in the study. Revision procedures or rTSA requiring glenoid bone graft were not included. Patients' demographics (age, sex, side, and body mass index), preoperative diagnosis, and glenoid wear patterns in both the coronal and axial planes were analyzed and defined as mild and severe. Postoperative implantation accuracy measurements were carried out on postoperative computed tomography scans and consisted of rTSA angle, version, maximal bone purchase of peripheral screws and central peg, and glenosphere eccentricity from the inferior glenoid neck. Results: 56 shoulders were included, 28 in each group. There were no significant differences in patient demographics, preoperative diagnosis, and wear pattern severity between both groups. In the navigated group, patients with severe bone wear presented a significantly higher accuracy in all analyzed parameters, whereas patients with mild glenoid defects did not show significant differences in the glenoid implantation version and glenosphere position from the inferior glenoid neck. Conclusion: Navigation significantly improves glenoid implantation accuracy, particularly in patients with severe glenoid wear patterns. While its applicability in standard cases is debatable for experienced shoulder surgeons, it could prove valuable for patients with severe bone defects. Further studies are needed to assess if this will impact clinical and long-term implant survival outcomes.

Indexed as

AccuracyBone purchaseGlenoid wearGlenosphere positioningNavigationReverse total shoulder arthroplasty

Identifiers

PMID40182268
PMCPMC11962623

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.