ArticleJSES international2025
Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models: an intraobserver repeatability and interobserver reproducibility study.
Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Deep Learning-Based Scapular Morphology Assessment Pipeline for Glenoid Segmentation and Landmark Localization.Journal of imaging informatics in medicine · 2026Article
- Glenohumeral internal rotation deficit after operative treatment of mid-shaft clavicle fractures: a subclinical, scapula-related phenomenon.Journal of orthopaedic surgery and research · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hypothesis: The primary objective of this study was to assess intraobserver repeatability and interobserver reproducibility of the 3-dimensional (3D) coordinates of a set of scapula anatomical landmarks obtained by manual positioning on conventional supine computed tomography (CT) scan-based scapula surface models. The secondary objective was to assess intraobserver repeatability and interobserver reproducibility of the resulting 3D scapular orientation. It was hypothesized that the 3D scapular orientation reliability would be better or similar than established reliability of intraoperative baseplate positioning (ie, version and inclination) in reverse total shoulder arthroplasty. Methods: Three anatomical landmarks, ie, acromial angle, inferior angle, and trigonum spinae, were manually positioned on 81 scapula surface models using updated landmark definitions. These models were obtained by the segmentation of CT scan images acquired from patients undergoing elective reverse total shoulder arthroplasty procedures at the Department of Surgery at Geneva University Hospitals between May 2022 and December 2023. This procedure was repeated 3 times per scapula by 3 independent observers. A set of parameters corresponding to the 3D landmark coordinates (expressed in an average scapula coordinate system) and the 3D scapular orientation (expressed as 3 angles related to the retraction/protraction, lateral/medial rotation, and internal/external rotation) were computed. Intraobserver repeatability and interobserver reproducibility were assessed for each of these parameters using an intraclass correlation coefficient (ICC) as a relative reliability metric. Standard error of measurement (SEM) was also reported as an absolute reliability metric. Results: Intraobserver ICC and interobserver ICC ranged from poor to moderate for acromial angle, poor to excellent for inferior angle, and poor to excellent for trigonum spinae. However, low SEM, ranging from 0.4 mm to 2.4 mm for intraobserver repeatability and from 0.2 mm to 1.8 mm for interobserver reproducibility, was obtained for every coordinate of each anatomical landmark. This results in poor to moderate intraobserver ICC and interobserver ICC for scapula angular orientation. Again, low SEM, ranging from 0.4° to 0.8° for intraobserver repeatability and 0.4° to 0.6° for interobserver reproducibility, was obtained, arguing for reliable measurements. Discussion: This study demonstrates that manual positioning of the 3 scapula anatomical landmarks recommended by the International Society of Biomechanics can be performed in a reliable manner across measures and observers on surface bone models obtained from CT scan images. However, a clear and standardized definition of these landmarks is needed to ensure consistency across measurements.