Evidence map›Paper›PMID 40182099›Full record

ArticlePostepy w kardiologii interwencyjnej = Advances in interventional cardiology2025

The role of aortic valve area in the quantitative flow ratio-fractional flow reserve discrepancy in patients with coronary artery disease and severe aortic stenosis.

Artur Dziewierz, Łukasz Rzeszutko, Łukasz Niewiara, Jacek Legutko, Paweł Kleczyński

Abstract read
In one paragraph

Article in Postepy w kardiologii interwencyjnej = Advances in interventional cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Ultreon 3.0 and physiological coronary assessment: initial single-center Polish experience.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Artur Dziewierz2 Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
Łukasz Rzeszutko2 Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
Łukasz NiewiaraDepartment of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
Jacek LegutkoDepartment of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
Paweł KleczyńskiDepartment of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The accuracy of fractional flow reserve (FFR) and quantitative flow ratio (QFR) in assessing coronary artery disease in severe aortic stenosis (AS) patients may be affected by the severity of AS. Aim: We investigated the relationship between aortic valve area (AVA) and the diagnostic performance of QFR in this context. Material and methods: We analyzed 416 intermediate coronary lesions in 221 severe AS patients using FFR and QFR, categorizing them based on AVA into two groups: AVA < 0.5 cm Results: In all, 47 (21.2%) patients had an AVA < 0.5 cm Conclusions: In severe AS, QFR closely correlates with FFR. However, patients with AVA < 0.5 cm

Indexed as

aortic stenosisdiscordancefractional flow reservefunctional assessmentquantitative flow ratio