Evidence map›Paper›PMID 40182038›Full record

ArticleFrontiers in oncology2025

Proton stereotactic centralized ablative radiation therapy for treating bulky tumor: a treatment plan study.

Tengxiang Li, Xinsen Yao, Ruimin He, Xian Xue, Shuai Wang, Jinhu Chen, Qingtao Qiu, Yong Yin, Quan Tang

Abstract read
In one paragraph

Article in Frontiers in oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tengxiang LiSchool of Nuclear Science and Technology, University of South China, Hengyang, China.
Xinsen YaoDepartment of Radiotherapy Center, Chenzhou NO.1 People's Hospital, Chenzhou, China.
Ruimin HeSchool of Nuclear Science and Technology, University of South China, Hengyang, China.
Xian XueInstitute of Radiation Protection and Nuclear Safety Medicine, Chinese Center for Disease Control and Prevention, Beijing, China.
Shuai WangDepartment of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China.
Jinhu ChenDepartment of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
Qingtao QiuDepartment of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
Yong YinSchool of Nuclear Science and Technology, University of South China, Hengyang, China.
Quan TangSchool of Nuclear Science and Technology, University of South China, Hengyang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Stereotactic centralized/core ablative radiation therapy (SCART) is a novel radiotherapy approach. This study investigates the potential benefits of proton-based SCART (pSCART) by leveraging the dosimetric advantages of protons and integrating them with the SCART technique. Methods: Five clinical cases previously treated with conventional proton therapy were selected for this study. The pSCART plans utilized a relative biological effectiveness (RBE) prescription dose of 24 Gy (RBE) × 3 fractions, with each plan consisting of three to five fields. The prescribed dose for the CyberKnife SCART was the highest value meeting the organs-at-risk (OARs) dose limits and the tumor edge dose limits. The dose distributions of the CyberKnife-based SCART and pSCART plans were compared using five criteria: i) prescription dose; ii) 80% prescription dose volume, targets coverage at 80% and 20% dose levels, and the 80%/20% ratio; iii) volume receiving >5 Gy outside the tumor edge; iv) dose tolerance limits to OARs; and v) mean dose to OARs. Results: pSCART can deliver a higher prescription dose of 24 Gy × 3 fractions versus SCART's 15 Gy × 2-3 fractions or 18 Gy × 2 fractions. Specifically, pSCART outperforms SCART in terms of the 80% prescription dose volume and 80% dose level coverage of stereotactic centralized/core target volumes (SCTV) achieving 69.77%-100.00% versus SCART's 43.6%-99.5%. The 20% dose level coverage for gross target volume (GTV) is slightly lower for pSCART, achieving 88.96%-98.64% versus SCART's 90.1%-99.9%. The maximum point dose outside the target volume is lower for pSCART at 4.58-6.19 Gy versus SCART's 4.78-6.67 Gy; additionally, the V Conclusions: This work provides initial insights into evaluating treatment plans for bulky tumors using pSCART. Compared to the CyberKnife SCART, pSCART generates significantly higher prescription doses and larger high-dose regions within the GTV while delivering lower doses at the tumor edge, enhancing normal tissue sparing.

Indexed as

bulky tumorcentralized/core ablativeprotonradiation therapystereotactic

Identifiers

PMID40182038
PMCPMC11965599

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.