ArticleESC heart failure2025
Multicentre comparison of various microaxial pump devices as a bridge to durable assist device implantation.
Article in ESC heart failure, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Temporary Mechanical Circulatory Support in Patients in Cardiogenic Shock Requiring Cardiac Surgery: Protected Cardiac Surgery Concept.Journal of clinical medicine · 2026Review
- Indication for durable mechanical circulatory support: an expert opinion review.ESC heart failure · 2026Review
- Article
- Article
- Multicentre comparison of various microaxial pump devices as a bridge to durable assist device implantation.ESC heart failure · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
33 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsPatients with acute decompensated advanced heart failure requiring left ventricular assist device (LVAD) implantation often experience progressive cardiac function deterioration, negatively impacting surgical outcomes. This study aimed to assess the efficacy of different microaxial flow pump (mAFP) support devices (Impella®) in achieving optimal left ventricular unloading for preconditioning and facilitating definitive treatment in this high-risk patient cohort. METHODS AND
resultsA retrospective analysis was conducted across 19 high-volume European centres. The study population included patients transitioning from temporary to durable circulatory support over a 7.5-year period, with a median follow-up of 1 year. Patients were categorized based on mAFP support capacity: those receiving high-flow support (>5 L/min, '5+') and those with lower-flow support (3.5 L/min, 'CP'). Patients who were initially treated with CP but subsequently upgraded to 5+ support were classified in the 5+ group. Demographic and clinical characteristics, mobilization, right heart function, and organ dysfunction outcomes were analysed. A total of 339 patients received preoperative mAFP support prior to LVAD implantation. The 5+ group comprised 247 patients (73%), including 38 patients who were upgraded from CP, while the CP group included 92 patients (27%). Baseline demographic and clinical characteristics were comparable between groups, except for mobilization status, which showed significant differences (P < 0.001). Patients in the 5+ group achieved higher rates of full and partial mobilization compared to the CP group. Extracorporeal life support (ECLS) was more frequently required in the CP group than in the 5+ group (40.5% vs. 33.8%; P < 0.001). Additionally, right ventricular assist device (RVAD) implantation was significantly more common in the CP group (29.2% vs. 18.2%; P = 0.026). Patients in the 5+ group demonstrated greater reductions in both vasoactive inotropic scores (P = 0.006) and inotropic scores (P = 0.008). Furthermore, liver dysfunction (P = 0.016), renal failure (P = 0.041), and the need for dialysis (P = 0.013) were significantly more prevalent in the CP group. There were no significant differences between the two groups in terms of LVAD operative duration (P = 0.637) or cardiopulmonary bypass time (P = 0.408).
conclusionsHigh-flow mAFP devices (+5) provided superior haemodynamic support, enhanced left ventricular unloading, and reduced dependence on catecholamines compared to lower-flow CP devices. These improvements were associated with lower rates of right ventricular failure, renal dysfunction, and liver injury. However, no statistically significant difference was observed between mAFP groups regarding 30-day mortality rates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.