ArticleOphthalmology science
Mechanical Property Comparison of 23-, 25-, and 27-Gauge Trocars across Multiple Pressures and Vitrectomy Systems.
Article in Ophthalmology science. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Objective: To investigate the mechanical properties of 23-, 25-, and 27-gauge trocars when subjected to representative pressures of posterior segment surgery. Design: Experimental study. Subjects: There were no subjects included in this study. Methods: Twenty-four trocars each from Alcon, Dutch Ophthalmic Research Center (DORC), and Bausch & Lomb (B/L), distributed evenly across 23-, 25-, and 27-gauge sizes were included in this study. These trocars were tested at both 40 mmHg and 60 mmHg of pressure. Two failure end points were identified, and each trocar was tested until it reached both failure points. Main Outcome Measures: The number of instrument exchanges required before trocar valve failure at 2 predesignated end points. Results: A total of 72 measurements were made. Most notably between brands, 23-gauge Alcon trocars demonstrated significantly greater competence than their 23-gauge counterparts in B/L and DORC at both 40 mmHg and 60 mmHg pressures ( Conclusions: Based on the findings of this study, 23-gauge valved trocars from B/L and DORC exhibited a significantly lower threshold for compromise compared to that of Alcon valved trocars, likely attributable to differences in valve placement design. Surgeon experience, vitrector preference, and the specific type of surgery performed are important considerations in the choice of vitrector gauge and brand. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.