Evidence map›Paper›PMID 40175556›Full record

ArticleScientific reports2025

Development of low cost ZnO based chemi resistive biosensor for the detection of vitamin B6 mediated by quantum dots.

Bhavana Anchan, Saritha Kamath U, Suresh D Kulkarni, Kavita A Pandey, Shounak De, Ajeetkumar Patil

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bhavana AnchanManipal Institute of Applied Physics (MIAP), Manipal Academy of Higher Education (MAHE), Manipal, 576 104, India.
Saritha Kamath UDepartment of Medical Laboratory Technology, Manipal College of Health Professions, Manipal Academy of Higher Education (MAHE), Manipal, 576 104, India.
Suresh D KulkarniManipal Institute of Applied Physics (MIAP), Manipal Academy of Higher Education (MAHE), Manipal, 576 104, India.
Kavita A PandeyCentre for Nano and Soft Matter Sciences (CeNS), Arkavathi, Survey No.7, Shivanapura, Dasanapura Hobli, Bengaluru, 562162, India.
Shounak DeDepartment of Electronics and Communication Engineering, Manipal Institute of Technology (MIT), Manipal Academy of Higher Education (MAHE), Manipal, 576104, India.
Ajeetkumar PatilManipal Institute of Applied Physics (MIAP), Manipal Academy of Higher Education (MAHE), Manipal, 576 104, India. ajeetkumar.p@manipal.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, we developed a chemi-resistive sensor for vitamin B6 mediated by CdTe quantum dots (Cadmium Telluride QDs) utilizing ZnO-based thin films through the spin-coating sol-gel technique annealed at 500 °C. The sensor successfully recognized vitamin B6 (Pyridoxine) in concentrations ranging from 2 to 10 µM by employing CdTe quantum dots (Cadmium Telluride QDs) on the ZnO thin film. This detection was achieved by implementing an amperometric (I-V) method, typically operating at a working voltage below 2 V. From the slope of the calibration curve, the sensitivity, and the limit of detection values are estimated to be 7.56 ± 0.92 nA/µM and 0.906 µM (n = 5), respectively. This study conducted electrochemical impedance spectroscopy (EIS) in conjunction with current-voltage (I-V) measurements. The results obtained from EIS are consistent with the current response observed in the I-V measurements. The sensing mechanism primarily relies on the charge transfer phenomenon (electrostatic attraction) between the analyte (vitamin B6 mediated by CdTe quantum dots) and the ZnO thin film. In summary, our work introduces a simple, rapid, and cost-effective ZnO thin film-based sensing device for detecting vitamin B6, mediated by CdTe QDs. This sensor holds promise for a wide range of applications, from pharmaceutical quality control to point-of-care diagnostics and routine vitamin B screening.

Indexed as

Biosensing TechniquesQuantum DotsVitamin B 6Zinc OxideCadmium CompoundsDielectric SpectroscopyLimit of DetectionTelluriumCadmium Compoundscadmium tellurideTelluriumVitamin B 6Zinc OxideBiosensorMetal oxide thin filmQuantum dotsVitamin B molecules

Identifiers

PMID40175556
PMCPMC11965439

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.