Evidence map›Paper›PMID 40175467›Full record

ArticleScientific reports2025

A deflectable video camera system for laparoscopic surgery based on shape memory alloy actuators.

Malte Pietsch, Konrad Henkel, René Körbitz, Ronny Hüttner, Kai Uhlig, Sascha Bruk, Matthieu Fischer, Jochen Hampe, Andreas Richter, Franz Brinkmann

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Malte Pietsch *TUD Dresden University of Technology, Chair of Microsystems, Dresden, SN, Germany.
Konrad Henkel *TUD Dresden University of Technology, Chair of Microsystems, Dresden, SN, Germany.
René KörbitzTUD Dresden University of Technology, Chair of Microsystems, Dresden, SN, Germany.
Ronny HüttnerTUD Dresden University of Technology, Chair of Microsystems, Dresden, SN, Germany.
Kai UhligIPF Leibniz Institute of Polymer Research Dresden, Dresden, SN, Germany.
Sascha BrukIPF Leibniz Institute of Polymer Research Dresden, Dresden, SN, Germany.
Matthieu FischerIPF Leibniz Institute of Polymer Research Dresden, Dresden, SN, Germany.
Jochen HampeDepartment of Medicine I, TUD Dresden University of Technology, Dresden University Hospital, Dresden, SN, Germany.
Andreas Richter *TUD Dresden University of Technology, Chair of Microsystems, Dresden, SN, Germany. andreas.richter7@tu-dresden.de.
Franz Brinkmann *Department of Medicine I, TUD Dresden University of Technology, Dresden University Hospital, Dresden, SN, Germany. franz.brinkmann@ukdd.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Laparoscopic instruments are usually not deflectable and therefore have significant usability limitations in minimally invasive surgery. Flexible-tip devices have been introduced, but they are still controlled by manual Bowden cables or conventional motors and are heavy and expensive. An interesting alternative are shape memory alloy (SMA) actuators, because they are lightweight, cost-efficient and offer the potential for a universal actuator platform for laparoscopic and other endoscopic instruments. This paper presents a laparoscopic video camera with electronic deflection control via thumb joystick. Its actuator unit consists of four SMA wires, whose special tensioning mechanism ensures both optimal preload and length compensation. The camera is tiltable in two degrees of freedom, enabled by a laser-cut Nitinol joint. Based on three assembled units and an automated measurement system, the functionality of the camera system was characterised. Deflection angles of more than 178° per degree of freedom were achieved. At operating frequencies of up to 0.5 Hz, the units showed suitable deflection behaviour. Each remained operational for more than 1200 actuation cycles or 4.4 h of continuous operation. Furthermore, the influence of continuous temperature stimulation on characteristic device parameters was investigated. This work contributes to demonstrating the feasibility of SMA actuators for the electrical control of flexible-tip laparoscopic instruments. Temperature control in particular is a challenge for future work.

Indexed as

AlloysLaparoscopyVideo RecordingEquipment DesignHumansAlloysnitinolEndoscopyLaparoscopic surgeryMedical roboticsShape memory alloysSmart materials

Identifiers

PMID40175467
PMCPMC11965422

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.