Evidence map›Paper›PMID 40170875›Full record

ArticleIEEE International Conference on Soft Robotics. IEEE International Conference on Soft Robotics2024

One-Piece 3D-Printed Pneumatic Catheter: Dual-Segment Design with Integrated Robotics Control for Endovascular Interventions.

Shaopeng Jiang, Lingyun Di, Noah Barnes, Hannah Qu, Olivia Young, Jeremy D Brown, Ryan Sochol, Axel Krieger

Abstract read
In one paragraph

Article in IEEE International Conference on Soft Robotics. IEEE International Conference on Soft Robotics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Bedside Admittance Control of a Dual-Segment Soft Robot for Catheter-Based Interventions.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shaopeng JiangLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Lingyun DiLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Noah BarnesDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Hannah QuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Olivia YoungDepartment of Mechanical Engineering, University of Maryland, College Park, MD, USA.
Jeremy D BrownDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Ryan SocholDepartment of Mechanical Engineering, University of Maryland, College Park, MD, USA.
Axel KriegerDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA.

Funding

3D-Nanoprinted Soft Robotic Microcatheters with Integrated Microfluidic Circuitry for Cerebrovascular SurgeryR01EB033354 · NIBIB · UNIV OF MARYLAND, COLLEGE PARK · PI SOCHOL, RYAN DANIEL · 2022 to 2025
$2.7M
NIBIB NIH HHS R01 EB033354
6 · The paper itself

Abstract

Soft robotics have propelled advancements in medical applications such as endovascular interventions through the development of soft steerable catheters. Despite their potential, existing catheters often require intricate manufacturing or complex control systems due to their inherent hysteresis and nonlinear material properties. This study introduces a novel catheter system featuring a 3D-printed hollow tip with two pneumatic bending units, facilitating rotation about two distinct axes without the need for additional fabrication steps. Finite element analysis simulations were used to optimize the catheter design while minimizing its diameter to 6.4 mm. Furthermore, an external robotic control system was integrated to perform physical experiments to assess the bending capabilities of the catheter tip. After calibration, the system exhibited proficient shape control, achieving a wide bending range from -47° to 169° under the integrated control system, and effectively conforming to 'C', 'S', and 'J' configurations with 0.53 degrees closed-loop accuracy. The catheter prototype demonstrated low hysteresis and high repeatability. The entire catheter system presents a pragmatic and cost-effective approach for the rapid prototyping and development of pneumatic steerable catheters. This novel system is ideally suited for testing preliminary concepts and educational applications in endovascular interventions.

Identifiers

PMID40170875
PMCPMC11956727

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.