ArticleMedical physics2025
Trade-off of different deep learning-based auto-segmentation approaches for treatment planning of pediatric craniospinal irradiation autocontouring of OARs for pediatric CSI.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Performance of adult-trained artificial intelligence models in paediatric imaging-a scoping review.European radiology · 2026Article
- Cell-free DNA methylation-based detection of organ damage following proton versus photon radiotherapy: a case series.Translational pediatrics · 2026Article
- Comparative Analysis of Atlas and Neural Network Autosegmentation Methods for Pediatric Craniospinal Irradiation With the Development of a Knowledge-Based Quality Assurance Tool.Advances in radiation oncology · 2025Article
- Trade-off of different deep learning-based auto-segmentation approaches for treatment planning of pediatric craniospinal irradiation autocontouring of OARs for pediatric CSI.Medical physics · 2025Article
- MDWC-Net: a multi-scale dynamic-weighting context network for precise spinal X-ray segmentation.Frontiers in physiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
backgroundAs auto-segmentation tools become integral to radiotherapy, more commercial products emerge. However, they may not always suit our needs. One notable example is the use of adult-trained commercial software for the contouring of organs at risk (OARs) of pediatric patients. PURPOSE: This study aimed to compare three auto-segmentation approaches in the context of pediatric craniospinal irradiation (CSI): commercial, out-of-the-box, and in-house.
methodsCT scans from 142 pediatric patients undergoing CSI were obtained from St. Jude Children's Research Hospital (training: 115; validation: 27). A test dataset comprising 16 CT scans was collected from the McGill University Health Centre. All images underwent manual delineation of 18 OARs. LimbusAI v1.7 served as the commercial product, while nnU-Net was trained for benchmarking. Additionally, a two-step in-house approach was pursued where smaller 3D CT scans containing the OAR of interest were first recovered and then used as input to train organ-specific models. Three variants of the U-Net architecture were explored: a basic U-Net, an attention U-Net, and a 2.5D U-Net. The dice similarity coefficient (DSC) assessed segmentation accuracy, and the DSC trend with age was investigated (Mann-Kendall test). A radiation oncologist determined the clinical acceptability of all contours using a five-point Likert scale.
resultsDifferences in the contours between the validation and test datasets reflected the distinct institutional standards. The lungs and left kidney displayed an increasing age-related trend of the DSC values with LimbusAI on the validation and test datasets. LimbusAI contours of the esophagus were often truncated distally and mistaken for the trachea for younger patients, resulting in a DSC score of less than 0.5 on both datasets. Additionally, the kidneys frequently exhibited false negatives, leading to mean DSC values that were up to 0.11 lower on the validation set and 0.07 on the test set compared to the other models. Overall, nnU-Net achieved good performance for body organs but exhibited difficulty differentiating the laterality of head structures, resulting in a large variation of DSC values with the standard deviation reaching 0.35 for the lenses. All in-house models generally had similar DSC values when compared against each other and nnU-Net. Inference time on the test data was between 47-55 min on a Central Processing Unit (CPU) for the in-house models, while it was 1h 21m with a V100 Graphics Processing Unit (GPU) for nnU-Net.
conclusionsLimbusAI could not adapt well to pediatric anatomy for the esophagus and the kidneys. When commercial products do not suit the study population, the nnU-Net is a viable option but requires adjustments. In resource-constrained settings, the in-house model provides an alternative. Implementing an automated segmentation tool requires careful monitoring and quality assurance regardless of the approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.