Evidence map›Paper›PMID 40170214›Full record

ArticleThe journal of trauma and acute care surgery2025

Novel silica-based polymer hemostatic matrix improves vessel patency rates in a coagulopathic porcine model with penetrating arterial injury.

Lauren M Heyda, Adelle M Dagher, John A Mares, Justin D Hutzler, Patrick F Walker, Jason Radowsky, Matthew Bradley, David M Burmeister

Abstract read
In one paragraph

Article in The journal of trauma and acute care surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lauren M HeydaFrom the Department of Surgery (L.M.H., A.M.D., P.F.W., J.R., M.B.), Walter Reed National Military Medical Center; Department of Surgery (J.A.M., J.D.H., P.F.W., J.R., M.B., D.M.B.), Uniformed Services University; Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc. (J.A.M., J.D.H.); and Department of Medicine (D.M.B.), Uniformed Services University, Bethesda, Maryland.
Adelle M Dagher
John A Mares
Justin D Hutzler
Patrick F Walker
Jason Radowsky
Matthew Bradley
David M BurmeisterORCID 0000-0002-1256-0158

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTraumatic hemorrhage is the leading cause of preventable battlefield death and hemostatic agents can improve survival. We compared a novel, amorphous, silica dioxide-based fiber (SBF) hemostatic matrix to the criterion standard QuikClot Combat Gauze (QCCG) in treating a junctional arterial injury in hypocoagulable swine.

methodsVascular access was obtained in 16 anesthetized swine, and hemodilution was achieved with 50% blood exchange with saline. A 5-mm arteriotomy was made in the common femoral artery. After 30 seconds of free bleeding, SBF or QCCG was applied, and pressure was held for 5 minutes. After 1 hour of monitoring, an angiogram and movement test were performed. Samples were drawn for blood count, chemistry, blood gas and rotational thromboelastography at various time points. The artery and hindlimb were collected for histology.

resultsAll animals (n = 8/group) survived. Hemodilution induced significant differences in hematocrit, platelets, clot formation time, and maximum clot firmness ( p < 0.0001). There was no difference in blood counts or chemistries ( p = 0.81-0.99) between groups at euthanasia. SBF required an average of 1.25 applications compared with 1.13 for QCCG ( p > 0.99). SBF had significantly less blood loss (106.2 ± 66.6 mL) versus QCCG (189.6 ± 78.9 mL, p = 0.038). Angiography revealed patency with distal perfusion in all (8/8) SBF-treated animals. Alternatively, all QCCG-treated arteries were occluded without distal perfusion, which was statistically significant ( p < 0.01). All animals remained hemostatic after the movement test. Blinded histopathological analysis revealed only two of eight cases of tunica intimal thickening and neutrophils in the QCCG group, which was not statistically different.

conclusionSBF and QCCG had comparable hemostatic efficacy and no difference in the number of applications, despite SBF packaging containing less material. There was no evidence of significant laboratory abnormalities at the study conclusion. Taken together, SBF may be an appropriate hemostatic agent for hemorrhagic injury and is able to maintain hemostasis following stressed movement. Its improved vessel patency suggests SBF may decrease tissue ischemia and improve limb salvage in vascular injuries.

Indexed as

ArteriesHemorrhageHemostaticsSilicon DioxideVascular PatencyVascular System InjuriesWounds, PenetratingAnimalsBandagesDisease Models, AnimalFemoral ArteryHemodilutionHemostatic TechniquesSwineHemostaticsSilicon Dioxidearterial injuryCoagulopathyhemostatic agentjunctional hemorrhageswine

Identifiers

PMID40170214
PMCPMC12321340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.