ArticleArchives of orthopaedic and trauma surgery2025
Intraoperative measurement of cup inclination using fluoroscopy: do we need a different correction factor when using a different C-arm model.
Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe direct anterior approach (DAA) in THA allows for intraoperative fluoroscopy imaging (IF). A previous study has shown that the intraoperative determination of radiographic cup inclination (RI) using IF during DAA THA is reliable and reproducible. However, a 5° correction factor should be applied to intraoperative measurements to adjust for parallax when using a standard 12-inch GE 9900 elite C-arm (GE Healthcare, Chicago, IL). The current study evaluates if the use of a flat panel C-arm requires a different correction factor. MATERIALS AND
methodsThe current study included 112 patients who underwent primary THA utilizing DAA with IF for cup placement. RI was measured using intraoperative fluoroscopy images of two different C-arm models (12-inch GE 9900 elite C-arm and OEC Elite flat panel and compared to postoperative AP pelvis radiographs.
resultsUsing the 12-inch GE 9900 elite C-arm (n = 76) mean intraoperative RI measurements (35.5°, range 28-42°) were on average 6.4° lower compared to mean postoperative measurements (41.9°, range 36-49°). Using the OEC Elite flat panel C-arm (n = 36) mean intraoperative RI measurements (36.1°, range 29-40°) were on average 5.6° lower compared to mean postoperative measurements (41.7°, range 37-48°).
conclusionThe current study confirms that a correction factor needs to be applied to intraoperative measurements of cup inclination to adjust for parallax regardless of the type of C-arm.