Evidence map›Paper›PMID 40167487›Full record

ArticleJournal of synchrotron radiation2025

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging.

Yoshihiro Obata, Dilworth Y Parkinson, Daniël M Pelt, Claire Acevedo

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yoshihiro ObataDepartment of Mechanical and Aerospace Engineering, University of California San Diego, San Diego, CA 92161, USA.ORCID 0000-0003-0365-9129
Dilworth Y ParkinsonAdvanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.ORCID 0000-0002-1817-0716
Daniël M PeltLeiden Institute of Advanced Computer Science (LIACS), Universiteit Leiden, 2333 CA Leiden, The Netherlands.
Claire AcevedoDepartment of Mechanical and Aerospace Engineering, University of California San Diego, San Diego, CA 92161, USA.ORCID 0000-0001-5425-3052

Funding

National Science Foundation 2045363U.S. Department of Energy, Office of Science DE-AC02-05CH11231
6 · The paper itself

Abstract

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Indexed as

Bone and BonesDeep LearningSynchrotronsX-Ray MicrotomographyAnimalsImage Processing, Computer-AssistedRadiation Dosagebone imagingconvolutional neural networksmachine learningmicrotomographyNoise2Inverse

Identifiers

PMID40167487
PMCPMC12067336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.