Evidence map›Paper›PMID 40165135›Full record

ArticleBMC pregnancy and childbirth2025

Effectiveness and clinical impact of using deep learning for first-trimester fetal ultrasound image quality auditing.

Xiaoyan Cao, Binghan Li, Yongsong Zhou, Yan Cao, Xin Yang, Xindi Hu, Chaoyu Chen, Shaokao Zhu, Hengli Lin, Tao Wang and 4 more

Abstract readMulticenter StudyValidation Study
In one paragraph

Article in BMC pregnancy and childbirth, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Xiaoyan Cao *Ultrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China.
Binghan Li *National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, 518073, China.
Yongsong ZhouNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, 518073, China.
Yan CaoShenzhen RayShape Medical Technology Co., Ltd., Shenzhen, Guangdong, 518071, China.
Xin YangNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, 518073, China.
Xindi HuShenzhen RayShape Medical Technology Co., Ltd., Shenzhen, Guangdong, 518071, China.
Chaoyu ChenNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, 518073, China.
Shaokao ZhuUltrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China.
Hengli LinUltrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China.
Tao WangUltrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China.
Yuling YanUltrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China.
Tao TanFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR, Taipa Island, 999078, China.
Lin WangUltrasound Department, Shenzhen Futian District Maternity & Child Healthcare Hospital, Shenzhen, Guangdong, 518016, China. 13728893488@163.com.
Dong NiNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, 518073, China.

Funding

Futian District Health and Health System Research Fund FTWS2023013National Natural Science Foundation of China Nos.62101343, 62171290Science and Technology Development Fund of Macao 0021/2022/AGJScience and Technology Planning Project of Guangdong Province 2023A0505020002Shenzhen Health Economics Association 2023149
6 · The paper itself

Abstract

backgroundRegular auditing of ultrasound images is required to maintain quality; however, manual auditing is time-consuming and can be inconsistent. We therefore aimed to develop and validate an artificial intelligence-based image quality audit (AI-IQA) system to audit images from the four key planes used in first-trimester scanning.

methodsThe AI-IQA system was developed based on the YOLOv7 structure detection network and a multi-branch image quality regression network using a large multicenter internal dataset. Clinical validation was performed using 567 cases scanned by four radiologists with different experience levels, of which 349 were performed without AI-IQA feedback (clinical test set 1) and 218 were performed after 2-3 rounds of AI-IQA feedback (clinical test set 2). The proportion of standard images obtained and detailed expert audit results were compared to verify whether AI-IQA could objectively and accurately provide feedback on deficiencies in nonstandard images to assist radiologists at different experience levels in improving image quality.

resultsIn the internal test set, the AI-IQA system achieved high average accuracy precision, recall and F1-score in auditing the overall plane quality (0.881, 0.833, 0.842 and 0.837, respectively) and structure quality (0.906, 0.861, 0.857 and 0.859, respectively). In clinical test sets 1 and 2, AI-IQA results showed strong consistency with expert assessment results, with the average Cohen's Kappa coefficient exceeding 0.8 for all four planes. In addition, following AI-IQA feedback, the proportion of standard images obtained by junior and mid-level radiologists increased by 7.7% and 5.1%, respectively. AI-IQA takes only 0.05 s to assess each image, while experts require more than 20 s (p < 0.001).

conclusionsThe proposed AI-IQA system proved to be a highly accurate and efficient method of automatically auditing first-trimester scanning image quality, providing precise and rapid key plane quality control. This tool can also assist radiologists with different levels of experience to improve the image quality.

Indexed as

Deep LearningMedical AuditUltrasonography, PrenatalClinical CompetenceFemaleHumansPregnancyPregnancy Trimester, FirstArtificial intelligenceDeep learningFirst-trimester scanningImage quality controlPrenatal ultrasound

Identifiers

PMID40165135
PMCPMC11956207

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.