Evidence map›Paper›PMID 40163362›Full record

ArticleJournal of synchrotron radiation2025

A high-energy Laue X-ray emission spectrometer at the FXE instrument at the European XFEL.

X Huang, Y Uemura, F Ardana-Lamas, P Frankenberger, M Knoll, H Yousef, H Wang, S Heder, M Nachtegaal, G Smolentsev and 4 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

X HuangEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-9140-6369
Y UemuraEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
F Ardana-LamasEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
P FrankenbergerEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
M KnollEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
H YousefEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
H WangEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
S HederEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
M NachtegaalCenter for Energy and Environmental Sciences, Paul Scherrer Institute, CH-5232 Villigen, Switzerland.ORCID 0000-0003-1895-9626
G SmolentsevCenter for Energy and Environmental Sciences, Paul Scherrer Institute, CH-5232 Villigen, Switzerland.
L WangDepartment of Modern Physics, University of Science and Technology of China, 230026 Hefei, People's Republic of China.
L F ZhuDepartment of Modern Physics, University of Science and Technology of China, 230026 Hefei, People's Republic of China.ORCID 0000-0002-5771-0471
C MilneEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0003-4714-9139
F A LimaEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0001-8106-2892

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The high-energy-resolution X-ray emission spectroscopy (XES) spectrometers available at the Femtosecond X-ray Experiment (FXE) instrument of the European XFEL operate in Bragg (reflective) geometry, with optimum performance in the range between 5 and 15 keV. However, they quickly lose efficiency above around 15 keV due to the decrease in reflectivity of the crystal analyzers at such high photon energies. This hampers high-energy-resolution spectroscopy experiments on heavy elements (e.g. 4d metals), which thus do not fully profit from the high-photon-energy capabilities of the European XFEL. Here we present the design, implementation and performance of a novel high-resolution XES spectrometer operating in Laue (transmission) geometry optimized for measurements at high photon energies (>15 keV). The High-Energy Laue X-ray emIssiOn Spectrometer (HELIOS) operates mainly in dispersive mode by placing the crystal analyzer inside or outside the Rowland circle. The Laue spectrometer performance in terms of energy resolution and efficiency is presented and discussed. Two Laue analyzers, silicon and quartz, have been tested at SuperXAS of the Swiss Light Source and at FXE of the European XFEL. The quartz analyzer was found to be about 2.7 times more efficient than the silicon one. The Laue spectrometer energy resolution (ΔE/E) reached at the FXE instrument is around 1.2 × 10

Indexed as

DuMond geometryLaue crystal analyzersultrafast scienceX-ray emission spectroscopyX-ray free-electron lasersX-ray spectrometers

Identifiers

PMID40163362
PMCPMC12067320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.