Evidence map›Paper›PMID 40161386›Full record

ArticleFrontiers in cardiovascular medicine2025

A novel method using body surface steel ball as a reference scale to measure the left atrial appendage for optimal selection of Watchman device.

He Jin, Mingjun Feng, Xianfeng Du, Binhao Wang, Yibo Yu, Guohua Fu, Caijie Shen, Huimin Chu

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

He JinCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Mingjun FengCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Xianfeng DuCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Binhao WangCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Yibo YuCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Guohua FuCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Caijie ShenCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Huimin ChuCardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Left atrial appendage closure (LAAC) is an alternative to oral anticoagulation for stroke prevention in non-valvular atrial fibrillation (AF). Selecting the appropriate size of Watchman device is very important intra-procedure. There are several methods have been reported to measure the left atrial appendage (LAA), but each of them has its limitations. Objective: We investigated the efficacy and safety of using the novel "steel ball method" compared to using the traditional "sheath method" and TEE during procedure of LAAC with Watchman device in AF patients. Methods: Patients with atrial fibrillation who underwent LAAC with Watchman device at The First Affiliated Hospital of Ningbo University from January 2018 to December 2021 were retrospectively analyzed. A 10 mm-diameter steel ball was placed on patient's body surface at the pulmonary valve auscultation zone before procedure. The maximum LAA ostium diameter, maximum LAA depth, and 1st sheath marker band length were measured under x-ray fluoroscopy, using the delivery sheath, pigtail sheath, and steel ball as references, respectively, which we called the delivery sheath group, pigtail sheath group and steel ball group. The maximum LAA ostium diameter and maximum LAA depth were also measured by TEE. All Watchman devices were selected based on the measurement of LAA by "steel ball method". The position of Watchman device and presence of peri-device leakage (PDL) were assessed using transesophageal echocardiography (TEE) before and after the release. Results: Eventually a total of 169 patients [63.3% male, age 69 (44-87) years, 73.4% persistent or permanent AF, CHA2DS2-VASc score 4.31 ± 1.54, HAS-BLED score 2.74 ± 1.15, left atrial diameter 44.09 ± 7.55 mm] underwent Watchman device implantation successfully were enrolled. The mean maximum LAA ostium diameter measured in steel ball group (24.73 ± 3.39 mm) was significantly higher than that in delivery sheath group (20.04 ± 3.24 mm, Conclusions: In LAAC, the novel method using body surface steel ball as a reference scale to measure the left atrial appendage and guide the selection of Watchman device is accurate, effective, and safe. The size of Watchman device may be too small if selection is based on the measurement results with "sheath method", which can lead to unsatisfactory outcome of the procedure.

Indexed as

left atrial appendage closuresheathsteel ballTEEWatchman

Identifiers

PMID40161386
PMCPMC11949990

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.